دورية أكاديمية

Potential value of Plasmodium falciparum-associated antigen and antibody detection for screening of blood donors to prevent transfusion-transmitted malaria.

التفاصيل البيبلوغرافية
العنوان: Potential value of Plasmodium falciparum-associated antigen and antibody detection for screening of blood donors to prevent transfusion-transmitted malaria.
المؤلفون: Silvie O, Thellier M, Rosenheim M, Datry A, Lavigne P, Danis M, Mazier D, Silvie, Olivier, Thellier, Marc, Rosenheim, Michel, Datry, Annick, Lavigne, Patricia, Danis, Martin, Mazier, Dominique
المصدر: Transfusion; Mar2002, Vol. 42 Issue 3, p357-362, 6p
مستخلص: Background: Malaria antibody detection is a valuable tool in the prevention of transfusion-transmitted malaria in countries with a high proportion of donors with travel exposure to malaria. The immunofluorescent antibody test (IFAT) is still the reference method, but it is not suitable for screening of blood donors. ELISA would be an interesting alternative to the IFAT, but it lacks sensitivity.Study Design and Methods: To evaluate the potential value of a combined screening strategy based on malaria antigen and antibody detection, plasma samples from 203 patients infected with Plasmodium falciparum were tested with an ELISA for the detection of malaria antibodies (Malaria IgG CELISA, Cellabs) and a P. falciparum histidine-rich protein-2 kit (Malaria P.f., ICT Diagnostics) for the detection of malaria antigens.Results: Among patients with positive IFAT results, CELISA had a sensitivity of 71 percent, whereas the combined screening tests (CELISA and Malaria P.f.) had a sensitivity of 88 percent (p < 0.001). Sequential samples from 50 patients were tested. The combined screening tests shortened the detection of seroconversion from 11.4 +/- 1.6 to 5.3 +/- 1.1 days (p < 0.001).Conclusion: Combined malaria antigen and antibody detection, with methods compatible with mass screening, may constitute an attractive alternative to the IFAT for blood donor screening. [ABSTRACT FROM AUTHOR]
Copyright of Transfusion is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00411132
DOI:10.1046/j.1537-2995.2002.00050.x