دورية أكاديمية

Performance of Different Accelerometry-Based Metrics to Estimate Oxygen Consumption during Track and Treadmill Locomotion over a Wide Intensity Range

التفاصيل البيبلوغرافية
العنوان: Performance of Different Accelerometry-Based Metrics to Estimate Oxygen Consumption during Track and Treadmill Locomotion over a Wide Intensity Range
المؤلفون: Henri Vähä-Ypyä, Jakob Bretterhofer, Pauliina Husu, Jana Windhaber, Tommi Vasankari, Sylvia Titze, Harri Sievänen
المصدر: Sensors, Vol 23, Iss 11, p 5073 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Chemical technology
مصطلحات موضوعية: accelerometer, adults, energy consumption, estimation, intensity, measurement, Chemical technology, TP1-1185
الوصف: Accelerometer data can be used to estimate incident oxygen consumption (VO2) during physical activity. Relationships between the accelerometer metrics and VO2 are typically determined using specific walking or running protocols on a track or treadmill. In this study, we compared the predictive performance of three different metrics based on the mean amplitude deviation (MAD) of the raw three-dimensional acceleration signal during maximal tests performed on a track or treadmill. A total of 53 healthy adult volunteers participated in the study, 29 performed the track test and 24 the treadmill test. During the tests, the data were collected using hip-worn triaxial accelerometers and metabolic gas analyzers. Data from both tests were pooled for primary statistical analysis. For typical walking speeds at VO2 less than 25 mL/kg/min, accelerometer metrics accounted for 71–86% of the variation in VO2. For typical running speeds starting from VO2 of 25 mL/kg/min up to over 60 mL/kg/min, 32–69% of the variation in VO2 could be explained, while the test type had an independent effect on the results, except for the conventional MAD metrics. The MAD metric is the best predictor of VO2 during walking, but the poorest during running. Depending on the intensity of locomotion, the choice of proper accelerometer metrics and test type may affect the validity of the prediction of incident VO2.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1424-8220
العلاقة: https://www.mdpi.com/1424-8220/23/11/5073Test; https://doaj.org/toc/1424-8220Test
DOI: 10.3390/s23115073
الوصول الحر: https://doaj.org/article/f39309110b4d49d0ade2489f2bea9b60Test
رقم الانضمام: edsdoj.f39309110b4d49d0ade2489f2bea9b60
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14248220
DOI:10.3390/s23115073