Delineation of the epileptogenic zone by Phase-amplitude coupling in patients with Bottom of Sulcus Dysplasia

التفاصيل البيبلوغرافية
العنوان: Delineation of the epileptogenic zone by Phase-amplitude coupling in patients with Bottom of Sulcus Dysplasia
المؤلفون: Hidenori Sugano, Yasushi Iimura, Takumi Mitsuhashi, Tetsuya Ueda, Hiroharu Suzuki, Kazuki Nishioka, Hiroshi Otsubo
المصدر: Seizure. 94:23-25
بيانات النشر: Elsevier BV, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Epilepsy, business.industry, General Medicine, Sulcus, Cortical dysplasia, medicine.disease, Epileptogenic zone, Magnetic Resonance Imaging, Electrophysiology, medicine.anatomical_structure, Nuclear magnetic resonance, Neurology, Dysplasia, Malformations of Cortical Development, Group I, medicine, Humans, In patient, Neurology (clinical), business, Subdural electrodes, Phase amplitude coupling
الوصف: Purpose The removal of the bottom of sulcus dysplasia (BOSD) often includes the gyral crown; however, this method has been controversial. We hypothesized that the epileptogenic zone of the BOSD does not include the gyral crown. To reveal the depth and extent of the epileptogenic zone of the BOSD, we applied the two electrophysiological modalities: (1) the occurrence rate (OR) of high-frequency oscillations (HFOs) and (2) modulation index (MI), reflecting the strength of phase-amplitude coupling between HFOs and slow oscillations. Methods We investigated the ripples [80-200 Hz] and fast ripples [200-300 Hz]) in HFOs and MI (HFOs [80-300 Hz] and slow oscillations [3-4 Hz]). We opened the sulcus at the BOSD and implanted the subdural electrodes directly over the MRI visible lesion. All patients (n = 3) underwent lesionectomy and the gyral crown was preserved. Results Pathological findings demonstrated focal cortical dysplasia type IIb and seizure freedom was achieved. The OR of the HFOs was not significantly different between the BOSD and the gyral crown. In contrast, the MI between HFOs and slow oscillations in the BOSD was significantly higher than that in the gyral crown. Conclusion High MI values distinguished the epileptogenic BOSD from the non-epileptogenic gyral crowns. MI could be a more informative biomarker of epileptogenicity than the OR of HFOs in a subset of patients with the BOSD.
تدمد: 1059-1311
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::31b50fbea00922bb1d683e8c79ed21d1Test
https://doi.org/10.1016/j.seizure.2021.11.006Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....31b50fbea00922bb1d683e8c79ed21d1
قاعدة البيانات: OpenAIRE