دورية أكاديمية

RADIATION TRANSPORT CALCULATIONS FOR 50 MV PHOTON THERAPY BEAM USING THE MONTE CARLO CODE GEANT4.

التفاصيل البيبلوغرافية
العنوان: RADIATION TRANSPORT CALCULATIONS FOR 50 MV PHOTON THERAPY BEAM USING THE MONTE CARLO CODE GEANT4.
المؤلفون: Larsson, Susanne, Svensson, Roger, Gudowska, Irena, Ivanchenko, Vladimir, Brahme, Anders
المصدر: Radiation Protection Dosimetry; 2005, Vol. 115 Issue 1-4, p503-507, 5p
مصطلحات موضوعية: RADIOTHERAPY, MONTE Carlo method, ELECTRON beams, MEDICAL radiology, ELECTROTHERAPEUTICS, PHOTON beams
مستخلص: A new thin transmission target technique for fast dose delivery using narrow scanned photon beams has been developed. High-energy, 50-100 MeV, electron beams of low emittance incident on thin low-Z targets produce narrow and intense high-energy bremsstrahlung beams. However, electrons transmitted through the target are bent from the therapeutic beam by a purging magnet and have to be effectively absorbed in a dedicated electron collector. The electron-photon transport through a treatment head has been studied using the Monte Carlo simulation toolkit Geant4. The Geant4 electromagnetic physics processes have been compared with experimental data of radial dose profiles. The differences between calculated and measured radial dose distributions are ∼2-10%. Preliminary investigations of the collector design have been carried out in order to minimise secondary electron and photon contamination of the therapeutic beam. The toolkit presented here is promising for further development of narrow photon beam therapy. [ABSTRACT FROM AUTHOR]
Copyright of Radiation Protection Dosimetry is the property of Oxford University Press / USA and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:01448420
DOI:10.1093/rpd/nci180