دورية أكاديمية

Removal of pulse artefact from EEG data recorded in MR environment at 3T. Setting of ICA parameters for marking artefactual components: application to resting-state data.

التفاصيل البيبلوغرافية
العنوان: Removal of pulse artefact from EEG data recorded in MR environment at 3T. Setting of ICA parameters for marking artefactual components: application to resting-state data.
المؤلفون: Eleonora Maggioni, Jorge Arrubla, Tracy Warbrick, Jürgen Dammers, Anna M Bianchi, Gianluigi Reni, Michela Tosetti, Irene Neuner, N Jon Shah
المصدر: PLoS ONE, Vol 9, Iss 11, p e112147 (2014)
بيانات النشر: Public Library of Science (PLoS), 2014.
سنة النشر: 2014
المجموعة: LCC:Medicine
LCC:Science
مصطلحات موضوعية: Medicine, Science
الوصف: Simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) allow for a non-invasive investigation of cerebral functions with high temporal and spatial resolution. The main challenge of such integration is the removal of the pulse artefact (PA) that affects EEG signals recorded in the magnetic resonance (MR) scanner. Often applied techniques for this purpose are Optimal Basis Set (OBS) and Independent Component Analysis (ICA). The combination of OBS and ICA is increasingly used, since it can potentially improve the correction performed by each technique separately. The present study is focused on the OBS-ICA combination and is aimed at providing the optimal ICA parameters for PA correction in resting-state EEG data, where the information of interest is not specified in latency and amplitude as in, for example, evoked potential. A comparison between two intervals for ICA calculation and four methods for marking artefactual components was performed. The performance of the methods was discussed in terms of their capability to 1) remove the artefact and 2) preserve the information of interest. The analysis included 12 subjects and two resting-state datasets for each of them. The results showed that none of the signal lengths for the ICA calculation was highly preferable to the other. Among the methods for the identification of PA-related components, the one based on the wavelets transform of each component emerged as the best compromise between the effectiveness in removing PA and the conservation of the physiological neuronal content.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1932-6203
العلاقة: http://europepmc.org/articles/PMC4226479?pdf=renderTest; https://doaj.org/toc/1932-6203Test
DOI: 10.1371/journal.pone.0112147
الوصول الحر: https://doaj.org/article/58db9d9229d14d0b86c006d523a9942dTest
رقم الانضمام: edsdoj.58db9d9229d14d0b86c006d523a9942d
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0112147