دورية أكاديمية

Use of Near-Infrared Spectroscopy to Monitor Lower Extremity Perfusion in Pediatric Patients Undergoing Cardiac Catheterization.

التفاصيل البيبلوغرافية
العنوان: Use of Near-Infrared Spectroscopy to Monitor Lower Extremity Perfusion in Pediatric Patients Undergoing Cardiac Catheterization.
المؤلفون: Herbert, Carrie E., Leshko, Jenny, Morelli, Dawn, Amankwah, Ernest, Hanson, Jade, Stapleton, Gary E.
المصدر: Pediatric Cardiology; Oct2019, Vol. 40 Issue 7, p1523-1529, 7p, 3 Charts, 2 Graphs
مصطلحات موضوعية: CARDIAC catheterization, LEG, OXIMETRY, CARDIAC patients, PERFUSION, FEMORAL artery, SPECTROMETRY
مستخلص: Acute femoral artery occlusion is common in pediatric patients following cardiac catheterization. A variety of means are utilized to assess lower extremity (LE) perfusion and arterial patency following cardiac catheterization including palpation of pulses, pulse oximetry, subjective assessment of lower extremity color and temperature, and ultrasound. We sought to evaluate the utility of Near-Infrared Spectroscopy (NIRS) to monitor LE perfusion in pediatric patients undergoing cardiac catheterization. INVOS pediatric sensors were placed on bilateral LE in all pediatric patients ≤ 40 kg undergoing cardiac catheterization. Data were recorded continuously from the start of the procedure until 4–6 h after completion of the procedure. NIRS readings were compared between the accessed versus non-accessed LE at baseline before start of case, time of vascular access, arterial sheath exchange when applicable, sheath withdrawal, and Safeguard application, deflation, and removal. 133 patients underwent 152 catheterizations with mean age 2.4 ± 2.3 years and mean weight 12.4 ± 13.2 kg. NIRS oximetry readings were significantly decreased in the LE with arterial access compared to non-accessed LE from time of sheath insertion until removal of the pressure assist device post procedure. A greater difference was noted in smaller patients. NIRS oximetry readings did not correlate with subjective assessment of lower extremity perfusion after arterial sheaths were removed. One patient had pulse loss 4 h post procedure with a decrease in oximetry readings noted at this point on review. Weight-based heparin protocol was initiated, and a gradual improvement in oximetry readings was noted over the next 5 h. Vascular ultrasound 12 h later showed no evidence of arterial thrombus. NIRS may be helpful in identifying patients who are risk for developing arterial thrombus post cardiac catheterization and for monitoring response to therapy; however, further study in these patients is warranted. [ABSTRACT FROM AUTHOR]
Copyright of Pediatric Cardiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:01720643
DOI:10.1007/s00246-019-02179-z