Biatrial volume, estimated using magnetic resonance imaging, predicts atrial fibrillation recurrence after ablation

التفاصيل البيبلوغرافية
العنوان: Biatrial volume, estimated using magnetic resonance imaging, predicts atrial fibrillation recurrence after ablation
المؤلفون: Tetsu Watanabe, Masafumi Watanabe, Yu Kumagai, Tamon Yamanaka, Sou Yamauchi, Tetsuro Shishido, Harutoshi Tamura, Isao Kubota, Daisuke Kutsuzawa, Tadateru Iwayama, Takanori Arimoto, Satoshi Nishiyama, Takuya Miyamoto, Hiroki Takahashi, Naoaki Hashimoto
المصدر: Pacing and Clinical Electrophysiology. 41:1635-1642
بيانات النشر: Wiley, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Epicardial Mapping, Male, medicine.medical_specialty, animal structures, medicine.medical_treatment, Catheter ablation, 030204 cardiovascular system & hematology, Pulmonary vein, 03 medical and health sciences, 0302 clinical medicine, Predictive Value of Tests, Recurrence, Left atrial, Cardiac magnetic resonance imaging, Internal medicine, Atrial Fibrillation, Image Interpretation, Computer-Assisted, medicine, Humans, Sinus rhythm, 030212 general & internal medicine, medicine.diagnostic_test, business.industry, Atrial fibrillation, Magnetic resonance imaging, General Medicine, Middle Aged, medicine.disease, Ablation, Magnetic Resonance Imaging, Treatment Outcome, Echocardiography, embryonic structures, Catheter Ablation, Cardiology, Female, Cardiology and Cardiovascular Medicine, business
الوصف: INTRODUCTION The predictive value of left atrial volume (LAV) in atrial fibrillation (AF) is known, but the relationship of right atrial volume (RAV) and biatrial volume (BAV) with AF recurrence after pulmonary vein isolation (PVI) is not clear. Cardiac magnetic resonance (CMR) imaging allows us to more precisely quantify atrial volume. We investigated LAV, RAV, and BAV as predictors of AF recurrence following PVI in AF patients. METHODS AND RESULTS We assessed 100 AF patients (age = 59.8 ± 9.5 years, 74 males, 26 females) who underwent nonenhanced CMR before their first PVI. LAV and RAV were measured using CMR. All patients were in sinus rhythm during CMR. BAV was calculated as the sum of LAV and RAV. During the 8-month follow-up, AF recurrence occurred in 23 patients. LAV, RAV, and BAV were significantly greater in patients with AF recurrence than in those without (LAV, 103.7 ± 25.8 vs 81.8 ± 24.2 mL, P
تدمد: 0147-8389
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::318d2f66d92bbeb99f73304fd2be75baTest
https://doi.org/10.1111/pace.13521Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....318d2f66d92bbeb99f73304fd2be75ba
قاعدة البيانات: OpenAIRE