Measurement of liquid holdup and axial dispersion in trickle bed reactors using radiotracer technique

التفاصيل البيبلوغرافية
العنوان: Measurement of liquid holdup and axial dispersion in trickle bed reactors using radiotracer technique
المؤلفون: Pant, H., Saroha, A., Nigam, K.
المصدر: Nukleonika.
مصطلحات موضوعية: axial dispersion model, holdup, mean residence time, Peclet number, residence time distribution, trickle-bed reactor
الوصف: The holdup and axial dispersion of aqueous phase has been measured in trickle bed reactors as a function of liquid and gas flow rates using radioisotope tracer technique. Experiments were carried out in a glass column of inner diameter 15.2´10-2 m column for air-water system using three different types of packings i.e. non-porous glass beads, porous catalysts of tablet and extrudate shape. The range of liquid and gas flow rates used were 8.3´10-5-3.3´10-4 m3/s and 0-6.67´10-4 m3/s, respectively. Residence time distributions of liquid phase were measured and mean residence times were determined. The values of liquid holdup were calculated from the measured mean residence times. It was observed that liquid holdup increased with increase in liquid flow rates and was independent of increase in gas flow rates used in the study. Two-parameter axial dispersion model was used to simulate measured residence time distribution data and values of mean residence time and Peclet number were obtained. It was observed that values of Peclet number increases with increase in liquid flow rate for glass beads and tablets and remains almost constant for extrudates. The values of mean residence time obtained from model simulation were found to be in good agreement with the values measured experimentally.
نوع الوثيقة: Article
اللغة: English
الوصول الحر: http://yadda.icm.edu.pl/baztech/element/bwmeta1.element.baztech-article-BUJ5-0004-0119Test
رقم الانضمام: edsbzt.bwmeta1.element.baztech.article.BUJ5.0004.0119
قاعدة البيانات: BazTech