دورية أكاديمية

Development and Validation of a Novel COVID-19 nsp8 One-Tube RT-LAMP-CRISPR Assay for SARS-CoV-2 Diagnosis

التفاصيل البيبلوغرافية
العنوان: Development and Validation of a Novel COVID-19 nsp8 One-Tube RT-LAMP-CRISPR Assay for SARS-CoV-2 Diagnosis
المؤلفون: Cyril Chik-Yan Yip, Siddharth Sridhar, Wan-Mui Chan, Jonathan Daniel Ip, Allen Wing-Ho Chu, Kit-Hang Leung, Vincent Chi-Chung Cheng, Kwok-Yung Yuen, Kelvin Kai-Wang To
المصدر: Microbiology Spectrum, Vol 10, Iss 6 (2022)
بيانات النشر: American Society for Microbiology, 2022.
سنة النشر: 2022
المجموعة: LCC:Microbiology
مصطلحات موضوعية: SARS-CoV-2, nsp8, RT-LAMP, CRISPR, diagnostic assay, Microbiology, QR1-502
الوصف: ABSTRACT Accurate and simple diagnostic tests for coronavirus disease 2019 (COVID-19) are essential components of the pandemic response. In this study, we evaluated a one-tube reverse transcription–loop-mediated isothermal amplification (RT-LAMP) assay coupled with clustered regularly interspaced short palindromic repeat (CRISPR)-associated protein-mediated endpoint detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in clinical samples. RT-LAMP-CRISPR is fast and affordable, does not require bulky thermocyclers, and minimizes carryover contamination risk. Results can be read either visually or with a fluorometer. RT-LAMP-CRISPR assays using primers targeting a highly expressed nsp8 gene and previously described nucleocapsid (N) gene primers were designed. The analytical characteristics and diagnostic performance of RT-LAMP-CRISPR assays were compared to those of a commercial real-time RT-PCR E gene assay. The limits of detection (LODs) of the nsp8 and N RT-LAMP-CRISPR assays were 750 and 2,000 copies/mL, which were higher than that of the commercial real-time RT-PCR assay (31.3 copies/mL). Despite the higher LOD, RT-LAMP-CRISPR assays showed diagnostic sensitivity and specificity of 98.6% and 100%, respectively, equivalent to those of the real-time RT-PCR assay (P = 0.5). The median fluorescence reading from the nsp8 assay (378.3 raw fluorescence unit [RFU] [range, 215.6 to 592.6]) was significantly higher than that of the N gene assay (342.0 RFU [range, 143.0 to 576.6]) (P
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2165-0497
العلاقة: https://doaj.org/toc/2165-0497Test
DOI: 10.1128/spectrum.01962-22
الوصول الحر: https://doaj.org/article/504cc0e230b84b088ffa18ecd53b3eb9Test
رقم الانضمام: edsdoj.504cc0e230b84b088ffa18ecd53b3eb9
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21650497
DOI:10.1128/spectrum.01962-22