دورية أكاديمية

The Effect of Home and In-Office Bleaching on Microhardness and Color of Different CAD/CAM Ceramic Materials

التفاصيل البيبلوغرافية
العنوان: The Effect of Home and In-Office Bleaching on Microhardness and Color of Different CAD/CAM Ceramic Materials
المؤلفون: Ruwaida Z. Alshali, Mohammed A. Alqahtani
المصدر: Materials, Vol 15, Iss 17, p 5948 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Technology
LCC:Electrical engineering. Electronics. Nuclear engineering
LCC:Engineering (General). Civil engineering (General)
LCC:Microscopy
LCC:Descriptive and experimental mechanics
مصطلحات موضوعية: bleaching, microhardness, color, ceramics, CAD/CAM, Technology, Electrical engineering. Electronics. Nuclear engineering, TK1-9971, Engineering (General). Civil engineering (General), TA1-2040, Microscopy, QH201-278.5, Descriptive and experimental mechanics, QC120-168.85
الوصف: The aim of this study is to assess the effect of different bleaching agents on microhardness and color of CAD/CAM ceramics including IPS e.max CAD (lithium disilicate), VITA ENAMIC (polymer-infiltrated ceramic), and Celtra Duo CAD (zirconia-reinforced lithium silicate). Materials’ samples were divided into three groups (n = 10) and each received a different bleaching treatment; 20% carbamide peroxide, 35% carbamide peroxide, and 40% hydrogen peroxide. A fourth group was stored in water acting as a control. Vickers microhardness and spectrophotometric color measurements were taken at baseline and after bleaching. IPS e.max CAD showed a significant reduction (about 14%), while VITA ENAMIC showed a significant increase (about 78%) in microhardness after bleaching (p ˂ 0.001). Celtra Duo CAD did not demonstrate a significant change in microhardness (p ≥ 0.609). The color difference (ΔEab) after bleaching was 0.29 (±0.08), 2.84 (±0.64), and 1.99 (±0.37) for IPS e.max CAD, VITA ENAMIC, and Celtra Duo CAD, respectively. It could be concluded that the effect of bleaching on color and microhardness was mainly material-dependent. Bleaching significantly affected the microhardness of IPS e.max CAD and VITA ENAMIC. The color difference was within the clinically imperceptible range for IPS e.max CAD, while VITA ENAMIC and Celtra Duo CAD demonstrated perceptible color change.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1996-1944
العلاقة: https://www.mdpi.com/1996-1944/15/17/5948Test; https://doaj.org/toc/1996-1944Test
DOI: 10.3390/ma15175948
الوصول الحر: https://doaj.org/article/16b1a6512d19449cacdc89c15f2f7b79Test
رقم الانضمام: edsdoj.16b1a6512d19449cacdc89c15f2f7b79
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19961944
DOI:10.3390/ma15175948