دورية أكاديمية

Performance of contrast-enhanced ultrasound (CEUS) in assessing thyroid nodules: a systematic review and meta-analysis using histological standard of reference.

التفاصيل البيبلوغرافية
العنوان: Performance of contrast-enhanced ultrasound (CEUS) in assessing thyroid nodules: a systematic review and meta-analysis using histological standard of reference.
المؤلفون: Trimboli, Pierpaolo, Castellana, Marco, Virili, Camilla, Havre, Roald Flesland, Bini, Fabiano, Marinozzi, Franco, D'Ambrosio, Ferdinando, Giorgino, Francesco, Giovanella, Luca, Prosch, Helmut, Grani, Giorgio, Radzina, Maija, Cantisani, Vito
المصدر: La Radiologia Medica; Apr2020, Vol. 125 Issue 4, p406-415, 10p
مستخلص: Background: The present study was undertaken to systematically review the literature on the reliability of using contrast-enhanced ultrasound (CEUS) to assess thyroid nodules. To avoid the potential bias in studies using a cytological standard of reference, here we aimed to meta-analyze data from studies adopting histological diagnosis as the gold standard. Methods: A comprehensive literature exploration of PubMed and Scopus was conducted. The search was updated until June 2018 and references of the retrieved articles screened. Only original articles reporting the histological follow-up of nodules previously undergone CEUS evaluation were eligible for inclusion. Pooled sensitivity, specificity, PPV, and NPV of CEUS were calculated by DerSimonian and Laird method (random-effects model). Results: The literature search retrieved 1885 articles, and 14 were included for the study. There were Chinese, Italian, German, and Austrian authors. All studies used SonoVue. The overall number of reported nodules was 1515, of which 775 were classified as positive at CEUS and 740 as negative. Pooled sensitivity, specificity, PPV, and NPV of CEUS were 85% (95% CI 83–88), 82% (95% CI 77–87), 83% (95% CI 77–88), and 85% (95% CI 81–88), respectively. Moderate inconsistency was present for specificity and PPV. There was publication bias for sensitivity and NPV. Conclusions: CEUS reaches good performance in discriminating between malignant and benign thyroid lesions. [ABSTRACT FROM AUTHOR]
Copyright of La Radiologia Medica is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index