Use of hyaluronidase in the comparison between manual and automated hematology analysis with the ADVIA 120 to improve analysis of feline body cavity effusions.

التفاصيل البيبلوغرافية
العنوان: Use of hyaluronidase in the comparison between manual and automated hematology analysis with the ADVIA 120 to improve analysis of feline body cavity effusions.
المؤلفون: Lee, Sei Ming, Williamson, Kenneth, Weir, William, Hulme-Moir, Lisa, Haining, Hayley
المصدر: Journal of Veterinary Diagnostic Investigation; Mar2017, Vol. 29 Issue 2, p212-216, 5p
مصطلحات موضوعية: CAT diseases, HYALURONIDASES, BLAND-Altman plot
مستخلص: Classification of body cavity effusions is an important step in the investigation and diagnosis of disease in cats. Feline inflammatory effusions are often highly proteinaceous and viscous, which can cause clumping of white cells and subsequently inaccurate nucleated cell counts (NCCs) using automated and manual methods. Microscopic assessment of cellularity can also be difficult given the variable thickness of smears and cell clumping, which skews white cell distribution. The ADVIA 120 uses 2 white cell–counting channels, the basophil/lobularity (WBC/baso) and differential/peroxidase channels, which can provide quite different results in highly viscous feline samples and often disagree with smear assessment of cellularity. We investigated the effects of pre-incubation of feline effusion samples with hyaluronidase and its effects on NCCs and cellularity assessment. NCCs were obtained by automated analysis using the ADVIA 120 and by manual counting methods. Agreement was assessed using a Bland–Altman chart. Pretreatment of samples with hyaluronidase resulted in good agreement between the ADVIA basophil channel and manual counting methods in all samples in the study. However, improvements in NCCs after hyaluronidase treatment were significantly greater in clumped samples, and cell distribution of these samples on direct smears was also improved. Therefore, when nucleated cell clumping is observed on a direct smear, pretreatment of the sample with hyaluronidase prior to analysis on an automated analyzer is advised, with the WBC/baso channel displaying the most accurate NCC. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Veterinary Diagnostic Investigation is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:10406387
DOI:10.1177/1040638716685133