Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults

التفاصيل البيبلوغرافية
العنوان: Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults
المؤلفون: Roberto Cantello, Francesco Brigo, Maurizio Leone, Piergiorgio Lochner, Lorenzo Coppo, Raffaele Nardone, Andrea Naldi
المصدر: Journal of Ultrasound. 19:41-45
بيانات النشر: Springer Science and Business Media LLC, 2014.
سنة النشر: 2014
مصطلحات موضوعية: Adult, Male, Optic nerve sheath, Interobserver reliability, business.operation, Transducers, optic nerve diameter, interobserver reliability, intraobserver reliability, optic nerve sheath diameter, tansorbital sonography, 03 medical and health sciences, 0302 clinical medicine, Internal Medicine, Humans, Medicine, Radiology, Nuclear Medicine and imaging, Aged, Ultrasonography, Aged, 80 and over, Reproducibility, business.industry, Ultrasound, Intraobserver reliability, Healthy subjects, Reproducibility of Results, Optic Nerve, 030208 emergency & critical care medicine, General Medicine, Middle Aged, Healthy Volunteers, Optic nerve, Original Article, Female, business, Nuclear medicine, Transorbital, 030217 neurology & neurosurgery
الوصف: Transorbital optic nerve sonography (TOS) can measure the optic nerve inclusive the sheath diameter (ONSD) and the optic nerve diameter (OND), which are useful parameters in the diagnosis of several neurological disorders. Data on the reproducibility of TOS are, however, required to use B-mode sonography for clinical purposes. The aim of this study was to assess intra- and interobserver reliability of ultrasound-based evaluations of both OND and ONSD in healthy subjects.Using a 4-11-MHz linear array transducer, the OND and ONSD of 20 healthy subjects were independently measured by two expert investigators.Depicting the optic nerve and its sheath was possible in all subjects. The intra- and interobserver reliability was high for both ONSD and OND measurements. Intraobserver agreement, analyzed with Cronbach´s Alpha, was higher for ONSD (range: 0.69-0.72) than for OND measurements (range: 0.55-0.65). No differences in interobserver reliability between ONSD and OND measurements were found (p = 0.83 for right and 0.47 for left eye).Transorbital B-mode sonography is a feasible method to assess both ONSD and OND with a high intra- and interobserver reliability. Technical difficulties in differentiating the optic nerve from its sheaths may explain the lower intraobserver agreement for OND than that for ONSD measurements.Due esaminatori hanno determinato in maniera indipendente valori di ONSD ed OND in 20 soggetti sani utilizzando una sonda ecografica a 4–11 MHz.In tutti i soggetti è stato possibile visualizzare il nervo ottico e i suoi rivestimenti. Sono stati ottenuti elevati valori di riproducibilità intra- e inter-osservatore nella determinazione dell'ONSD e dell'OND. La riproducibilità intra-osservatore, analizzata con il metodo del Cronbach´s Alpha, era maggiore per l'ONSD (range: 0.69–0.72) che per l'OND (range 0.55–0.65). Non sono state riscontrate differenze nella riproducibilità inter-osservatore tra ONSD ed OND (La TOS è un metodo in grado di ottenere i valori di ONSD ed OND con elevato grado di riproducibilità intra- ed inter-osservatore. Difficoltà tecniche nel distinguere il nervo ottico dai suoi rivestimenti possono spiegare il minor grado di riproducibilità intra-osservatore per l'OND rispetto all'ONSD.
تدمد: 1876-7931
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::97a3881bfc96e9b162955adebdc3f021Test
https://doi.org/10.1007/s40477-014-0144-zTest
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....97a3881bfc96e9b162955adebdc3f021
قاعدة البيانات: OpenAIRE