Grip strength comparison in immune-mediated neuropathies: Vigorimeter vs. Jamar

التفاصيل البيبلوغرافية
العنوان: Grip strength comparison in immune-mediated neuropathies: Vigorimeter vs. Jamar
المؤلفون: Catharina G. Faber, W. Ludo van der Pol, Vera Bril, Kenneth C. Gorson, Peter Van den Bergh, Sonja I. van Nes, Mayienne Bakkers, Ingemar S. J. Merkies, Michael P. Lunn, Leonard H. van den Berg, Eduardo Nobile-Orazio, Hans D. Katzberg, Anneke J. van der Kooi, Nicolette C. Notermans, Richard A. Lewis, Els K. Vanhoutte, Angelika F. Hahn, Pieter A. van Doorn, Mariëlle H J Pruppers, Jean Marc Léger, Jean Pouget, David R. Cornblath, Thomas H P Draak, Giuseppe Lauria
المصدر: Journal of the Peripheral Nervous System. 20:269-276
بيانات النشر: Wiley, 2015.
سنة النشر: 2015
مصطلحات موضوعية: medicine.medical_specialty, General Neuroscience, Minimal clinically important difference, Mismatch negativity, Polyradiculoneuropathy, medicine.disease, Grip strength, medicine, Comparison study, Physical therapy, In patient, Neurology (clinical), Psychology, Polyneuropathy, Multifocal motor neuropathy
الوصف: The Jamar dynamometer and Vigorimeter have been used to assess grip strength in immune-mediated neuropathies, but have never been compared to each other. Therefore, we performed a comparison study between these two devices in patients with immune-mediated neuropathies. Grip strength data were collected in 102 cross-sectional stable and 163 longitudinal (new diagnoses or changing condition) patients with Guillain-Barre syndrome (GBS), chronic inflammatory demyelinating polyradiculoneuropathy (CIDP), gammopathy-related polyneuropathy (MGUSP), and multifocal motor neuropathy (MMN). Stable patients were assessed twice (validity/reliability studies). Longitudinal patients were assessed 3-5 times during 1 year. Responsiveness comparison between the two tools was examined using combined anchor-/distribution-based minimum clinically important difference (MCID) techniques. Patients were asked to indicate their preference for the Jamar or Vigorimeter. Both tools correlated highly with each other (ρ = 0.86, p < 0.0001) and showed good intra-class correlation coefficients (Jamar [Right/Left hands]: ICC 0.997/0.96; Vigori: ICC 0.95/0.98). Meaningful changes were comparable between the two instruments, being higher in GBS compared to CIDP patients. In MGUSP/MMN poor responsiveness was seen. Significant more patients preferred the Vigorimeter. In conclusion, validity, reliability, and responsiveness aspects were comparable between the Jamar dynamometer and Vigorimeter. However, based on patients' preference, the Vigorimeter is recommended in future studies in immune-mediated neuropathies.
تدمد: 1085-9489
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_________::c5c63f05a91a01f99be98de4e90023f3Test
https://doi.org/10.1111/jns.12126Test
حقوق: CLOSED
رقم الانضمام: edsair.doi...........c5c63f05a91a01f99be98de4e90023f3
قاعدة البيانات: OpenAIRE