Evaluation of stray neutron distribution in medical cyclotron vault room by neutron activation analysis approach.

التفاصيل البيبلوغرافية
العنوان: Evaluation of stray neutron distribution in medical cyclotron vault room by neutron activation analysis approach.
المؤلفون: Jye-Bin Lin, Jui-Ping Lee, Ding-Bang Lin, Wen-Kang Chen, Wen-Shan Liu, Chien-Yi Chen
المصدر: Journal of Radioanalytical & Nuclear Chemistry; Jun2009, Vol. 280 Issue 3, p481-487, 7p, 1 Chart, 5 Graphs
مصطلحات موضوعية: NUCLEAR activation analysis, NEUTRONS, CYCLOTRONS, RADIOISOTOPES, INDIUM, GAMMA rays
مستخلص: Stray neutron distribution in a medical cyclotron vault room was evaluated by neutron activation analysis (NAA). Neutrons were generated in the production of radioactive nuclides, such as 18F, 11C, 13N and 15O, for diagnostic usage. Indium foil was adopted to evaluate the stray fast and thermal neutron intensity based on 115In(nf, n′)115mIn and 115In(nth, γ)116m1In reactions, respectively. The indium foils were weighed, sealed and placed at 62 points around the 6.7×8.2 m2 cyclotron room. Additionally, each indium foil was exposed for over 80 minutes during cyclotron operation and γ-peaks were analyzed using an HPGe detector to evaluate the number of stray fast ( Φf) or thermal ( Φth) neutrons. The minimum to maximum numbers of fast and thermal neutrons were (3.47±0.11)×103 to (1.06±0.21)×104 n·cm−2·s−1 and 9 to 965 n·cm−2·s−1, respectively. The minimum detectable limit for stray neutrons was included herein to demonstrate the reliability. Accordingly, 60 and two points, respectively, the confidence level associated with the reported intensities of fast and thermal neutrons reached 95%. The low qualified ratio in the evaluation of stray thermal neutrons might have been caused by either the high Compton scattering plateau or the low intensity of the gamma-ray peak in the relevant spectrum. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Radioanalytical & Nuclear Chemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:02365731
DOI:10.1007/s10967-009-7461-2