High-Resolution Phased-Array MRI of the Human Brain at 7 Tesla: Initial Experience in Multiple Sclerosis Patients

التفاصيل البيبلوغرافية
العنوان: High-Resolution Phased-Array MRI of the Human Brain at 7 Tesla: Initial Experience in Multiple Sclerosis Patients
المؤلفون: Radhika Srinivasan, Daniel B. Vigneron, Sarah J. Nelson, Douglas A.C. Kelley, Darin T. Okuda, Meredith Metcalf, Duan Xu, Lucas Carvajal, Daniel Pelletier, Pratik Mukherjee
المصدر: Journal of Neuroimaging. 20:141-147
بيانات النشر: Wiley, 2010.
سنة النشر: 2010
مصطلحات موضوعية: Adult, Male, Pathology, medicine.medical_specialty, Multiple Sclerosis, Phased array, Transducers, High resolution, Pilot Projects, Nerve Fibers, Myelinated, Sensitivity and Specificity, Article, White matter, Magnetics, medicine, Humans, Radiology, Nuclear Medicine and imaging, Aged, medicine.diagnostic_test, business.industry, Multiple sclerosis, Brain, Reproducibility of Results, Magnetic resonance imaging, Equipment Design, Human brain, Middle Aged, Image Enhancement, medicine.disease, Magnetic Resonance Imaging, Mr imaging, Image contrast, Equipment Failure Analysis, medicine.anatomical_structure, Female, Neurology (clinical), Nuclear medicine, business
الوصف: Recent advancement for magnetic resonance imaging (MRI) involves the incorporation of higher-field strengths. Although imagers with higher magnetic field strengths were developed and tested in research labs, the direct application to patient MR studies have been extremely limited. Imaging at 7 Tesla (7T) affords advantages in signal-to-noise ratio and image contrast and resolution; however, these benefits can only be realized if the correct coils exist to capture the images. The objective of this study was to develop optimized high-resolution 7T MRI techniques using high sensitivity, specialized phased-array coils, for improved gray matter (GM) and white matter differentiation, in an effort to improve visualization of multiple sclerosis (MS) lesions in vivo. Twenty-three subjects were enrolled in this preliminary study, 17 with clinically definite MS (11 females, 6 males; mean age 43.4 years; range 22-64 years) and 6 healthy controls (2 females, 4 males; mean age 39.0 years; range 27-67 years). MR imaging of MS patients at 7T was demonstrated to be safe, well tolerated, and provided high-resolution anatomical images allowing visualization of structural abnormalities localized near or within the cortical layers. Clear involvement of the GM was observed with improved morphological detail in comparison to imaging at lower-field strength.
تدمد: 1552-6569
1051-2284
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::32fbf870c5d7b8ab29c02bc4414b3ca3Test
https://doi.org/10.1111/j.1552-6569.2008.00338.xTest
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....32fbf870c5d7b8ab29c02bc4414b3ca3
قاعدة البيانات: OpenAIRE