دورية أكاديمية

Assessing the test–retest repeatability of insulin resistance measures: Homeostasis model assessment 2 and oral glucose insulin sensitivity

التفاصيل البيبلوغرافية
العنوان: Assessing the test–retest repeatability of insulin resistance measures: Homeostasis model assessment 2 and oral glucose insulin sensitivity
المؤلفون: Catherine A.P. Crofts, Mark C. Wheldon, Caryn Zinn, Xiaomiao Lan-Pidhainy, Thomas M.S. Wolever, Grant Schofield
المصدر: Journal of Metabolic Health, Vol 2, Iss 1, Pp e1-e9 (2017)
بيانات النشر: AOSIS, 2017.
سنة النشر: 2017
المجموعة: LCC:Medicine
مصطلحات موضوعية: homa, insulin resistance, ogis, repeatability, Medicine
الوصف: Background: Insulin resistance is commonly assessed using the homeostasis model assessment (HOMA) variants. HOMA is potentially insensitive to change because of its high coefficient of variation. The repeatability coefficient is an alternative means of assessing test repeatability. To be confident of clinical change, rather than biological variation, a subsequent test needs to differ from the former by more than the repeatability coefficient using the equation. Test 1 = Test 2 ± repeatability coefficient. The repeatability coefficients for measures of insulin resistance are unknown. Aim: To compare the repeatability coefficient of HOMA2 variants (Beta-cell function [%B], insulin sensitivity [%S], insulin resistance [IR]) to a dynamic measure of insulin resistance, and the oral glucose insulin sensitivity (OGIS) test. Setting: The raw data from a previously used data set were reanalysed. Methods: Glycaemic and insulinaemic tests were performed on 32 men and women both with (n = 10) and without type 2 diabetes (n = 22). From these data, eight fasting tests and three 50-g oral glucose tolerance tests were used to calculate HOMA2 and OGIS. The methods of Bland and Altman assessed repeatability. Results: Repeatability coefficients for all participants for the HOMA2 %B, %S and IR variants were 72.91, 189.75 and 0.9, which equates to 89%, 135% and 89% of their respective grand means. By contrast, OGIS had a repeatability coefficient of 87.13, which equates to 21% of the grand mean. Conclusion: Because of the high repeatability coefficient relative to the grand mean, use of HOMA2 measures for assessing insulin resistance in small population studies should be reconsidered.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2960-0391
العلاقة: https://journalofmetabolichealth.org/index.php/jmh/article/view/27Test; https://doaj.org/toc/2960-0391Test
DOI: 10.4102/jir.v2i1.27
الوصول الحر: https://doaj.org/article/587d45e893e541c79c95d12c41aaff51Test
رقم الانضمام: edsdoj.587d45e893e541c79c95d12c41aaff51
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:29600391
DOI:10.4102/jir.v2i1.27