Aortic Annulus Measurement and Relevance to Successful Transcatheter Aortic Valve Replacement: A New Technique Using 3D TEE.

التفاصيل البيبلوغرافية
العنوان: Aortic Annulus Measurement and Relevance to Successful Transcatheter Aortic Valve Replacement: A New Technique Using 3D TEE.
المؤلفون: PERSHAD, ASHISH, STONE, DIANA, MORRIS, MICHAEL F., FANG, KENITH, GELLERT, GEORGE
المصدر: Journal of Interventional Cardiology; Jun2013, Vol. 26 Issue 3, p302-309, 8p, 4 Color Photographs, 1 Black and White Photograph, 3 Diagrams, 2 Charts
مصطلحات موضوعية: AORTIC valve surgery, ECHOCARDIOGRAPHY, MEDICAL imaging systems, THREE-dimensional imaging, CARDIAC contraction, ANESTHESIOLOGISTS, TOMOGRAPHY
مستخلص: Background There are limitations of using 2D imaging to accurately size the aortic annulus. This article highlights the limitations of 2D technology and proposes a new 3D TEE method for sizing of the aortic annulus. Methods Three-dimensional echocardiography with the method described can identify the 'true' aortic annulus with precision. A 3D dataset of the aortic annulus is collected. The 3D quantification program is then activated. The three multiplanar reconstruction planes (the aortic short-axis, long-axis, and coronal planes) are aligned during systole, to obtain the 3 nadirs of the sinuses of Valsalva simultaneously in the short-axis MPR. Rotating the sagittal and coronal planes to identify the hinge points is necessary to measure the diameter of the 'true' annulus. The 'true' aortic annulus is defined by the blood-tissue interface in the aortic short-axis MPR. Results This method has been prospectively validated with surgical AVR sizing in a small study of 10 patients. During surgical AVR, the annulus was directly measured using a sizer. This served as a gold standard for comparison. The annulus was measured using the method described in a blinded fashion by the cardiac anesthesiologist and then confirmed offline by a blinded echocardiographer. In this small study, the Pearson correlation coefficient was 0.9833 with 23.4 and 23.22 mm being the mean measurements with the 2 methods. Discussion The method described in this article is complementary to multidetector computed tomography and provides a real-time measurement of the annulus during the TAVR procedure without need for radiographic contrast. (J Interven Cardiol 2013;26:302-309) [ABSTRACT FROM AUTHOR]
Copyright of Journal of Interventional Cardiology is the property of Hindawi Limited and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:08964327
DOI:10.1111/joic.12033