دورية أكاديمية

Fluorescent Analysis for Bioindication of Ozone on Unicellular Models.

التفاصيل البيبلوغرافية
العنوان: Fluorescent Analysis for Bioindication of Ozone on Unicellular Models.
المؤلفون: Roshchina, Victoria, Yashin, V., Kuchin, A.
المصدر: Journal of Fluorescence; May2015, Vol. 25 Issue 3, p595-601, 7p
مصطلحات موضوعية: OZONE spectra, FLUORESCENCE spectroscopy, EQUISETUM, HAZEL, AFRICAN violets, LIPOFUSCINS, CATECHOLAMINES, HISTAMINE
مستخلص: Unicellular model plant systems (vegetative microspores of horsetail Equisetum arvense and pollen of six plant species Corylus avellana, Dolichothele albescens Populus balsamifera, Salix caprea, Saintpaulia ionantha, Tulipa hybridum, on which autofluorescence and fluorescence after histochemical treatment studied, have been represented as bioindicators of ozone. It has found that low doses of ozone 0.005 or 0.008 μl/l did not affect or stimulate the autofluorescence of the samples with the ability to germinate in an artificial medium. In higher ozone concentrations (0.032 μl/l) either the decrease in the intensity of the emission or changing in the position of the maxima in the fluorescence spectrum (new 515-520 nm maximum characteristic for the green-and yellow area has appeared) were observed. In dose of 0.2 μl/l, higher than above the threshold of danger to human health, autofluorescence in all samples fell down to up to zero, and there was no the ability to germinate. In this case the formation of lipofuscin-like compounds fluoresced in blue with maxima from 440 to 485 nm was observed. Stress metabolites, known as neurotransmitters biogenic amines, were found in treated cells as determined on the characteristic fluorescence at 460-480 nm in the samples after a specific histochemical reactions for catecholamines (with glyoxylic acid) or for histamine (with o-phthalic aldehyde). Increased intensity of the emission under the treatment with ozone (total doses from 0.012 to 0.032 μl/l) was associated with an increase in the concentrations of catecholamines and histamine. The fluorescent analysis on undamaged cells-possible bioindicators of ozone can be useful in ecomonitoring for earlier warning about health hazardous concentrations of this compound in the air. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Fluorescence is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:10530509
DOI:10.1007/s10895-015-1540-2