Clinical relevance of double-arm blood pressure measurement and prevalence of clinically important inter-arm blood pressure differences in Indian primary care

التفاصيل البيبلوغرافية
العنوان: Clinical relevance of double-arm blood pressure measurement and prevalence of clinically important inter-arm blood pressure differences in Indian primary care
المؤلفون: Gurpreet S. Wander, Sinead T.J. McDonagh, M. Srinivasa Rao, R. Alagesan, JC Mohan, Ajit Bhagwat, AK Pancholia, M. Viswanathan, Manoj Bhavrilal Chopda, A Purnanand, PLN kapardhi, Arun R Vadavi, R Selvaraj, Pankaj Aneja, Suhas Hardas, Neil Bordoloi, N Sivakadaksham, Christopher E goswami, Christopher E Clark, Willem J. Verberk
المساهمون: RS: Carim - V02 Hypertension and target organ damage
المصدر: Journal of Clinical Hypertension, 24(8), 993-1002. Wiley
سنة النشر: 2022
مصطلحات موضوعية: Male, hypertension, Endocrinology, Diabetes and Metabolism, ACCURACY, inter-arm blood pressure difference, Endocrine System Diseases, DIAGNOSIS, GUIDELINES, PROFESSIONAL DEVICE, Adrenocorticotropic Hormone, cardiovascular disease, Prevalence, Internal Medicine, Humans, Primary Health Care, Genetic Diseases, Inborn, blood pressure, Blood Pressure Determination, VASCULAR-DISEASE, ASSOCIATION, Middle Aged, PREVENTION, Hypoglycemia, ATRIAL-FIBRILLATION, Female, Cardiology and Cardiovascular Medicine, MICROLIFE WATCHBP OFFICE
الوصف: Hypertension guidelines recommend measuring blood pressure (BP) in both arms at least once. However, this is seldom done due to uncertainties regarding measurement procedure and the implications of finding a clinically important inter-arm BP difference (IAD). This study aimed to provide insight into the prevalence of clinically important IADs in a large Indian primary care cohort. A number of 134678 (37% female) unselected Indian primary care participants, mean age 45.2 (SD 11.9) years, had BP measured in both arms using a standardized, triplicate, automated simultaneous measurement method (Microlife WatchBP Office Afib). On average, there were clinically minor differences in right and left arm BP values: systolic BP 134.4 vs. 134.2 mmHg (p0.01) and diastolic BP 82.7 vs. 82.6 mmHg (p0.01), respectively. Prevalence of significant mean systolic IAD between 10 and 15 mmHg was 7813 (5.8%). Systolic IAD ≥ 15 mmHg 2980 (2.2%) and diastolic IAD ≥ 10 mmHg 7151 (5.3%). In total, there were 7595 (5.6%) and 8548 (6.3%) participants with BP above the 140/90 mmHg threshold in only the left or right arm, respectively. Prevalence of participants with elevated BP on one arm only was highest in patients with a systolic IAD ≥ 15 mmHg; 19.1% and 13.7%, for left and right arm, respectively. This study shows that a substantial prevalence of IAD exist in Indian primary care patients. BP is above the diagnostic threshold for hypertension in one arm only for 6% of participants. These findings emphasise the importance of undertaking bilateral BP measurement in routine clinical practice. This article is protected by copyright. All rights reserved.
اللغة: English
تدمد: 1524-6175
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7ff8ce1dda995e14f247804b4e9b6830Test
https://doi.org/10.1111/jch.14497Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....7ff8ce1dda995e14f247804b4e9b6830
قاعدة البيانات: OpenAIRE