In vitro optical quality differences between multifocal apodized diffractive intraocular lenses

التفاصيل البيبلوغرافية
العنوان: In vitro optical quality differences between multifocal apodized diffractive intraocular lenses
المؤلفون: Robert Montés-Micó, Teresa Ferrer-Blasco, David Madrid-Costa, Álvaro Pons, Javier Ruiz-Alcocer
المصدر: Journal of cataract and refractive surgery. 39(6)
سنة النشر: 2012
مصطلحات موضوعية: Physics, Lenses, Intraocular, Focal point, Optics and Photonics, business.industry, Aperture, Prosthesis Design, Sensory Systems, Optical quality, Ophthalmology, Optics, Cardinal point, Apodization, Intraocular lenses, Optical transfer function, Surgery, Visual Fields, business, Dioptre, Vision, Ocular
الوصف: Purpose To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifocal IOL with 3 main foci (trifocal IOL) were evaluated. The optical quality was quantified using the modulation transfer function (MTF) at 7 focal points and for 3.0 mm and 4.5 mm apertures. The through-focus MTF at 10 focal points of the IOLs was also recorded. Results For the 0.0 D and −2.5 D focal points, the bifocal IOL showed the highest MTF values for pupil sizes as well as for the −3.0 D focal point for a 3.0 mm aperture. For the −1.5 D and −3.5 D focal points, the trifocal IOL provided better MTF values, whereas for −2.0 D and −4.0 D both IOLs provided comparable results for both apertures. The through-focus MTF curves showed 3 and 2 peaks for the trifocal IOL and the bifocal IOL, respectively. With the bifocal IOL, better peak values were obtained at the 0.0 D, −2.0 D, −2.5 D, and −3.0 D focal points, while the trifocal IOL yielded better peak values at the −1.5 D and −3.5 D focal points. Conclusion The bifocal IOL is likely to provide a greater range of vision from distance to near than the trifocal IOL; however, at the intermediate focal point (−1.5 D), the trifocal IOL will probably yield better optical quality. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
تدمد: 1873-4502
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::593c87c345f5d71148b1e4c3cb83dc08Test
https://pubmed.ncbi.nlm.nih.gov/23688880Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....593c87c345f5d71148b1e4c3cb83dc08
قاعدة البيانات: OpenAIRE