The influence of the electrodes spacing of a mapping catheter on the atrial voltage substrate map

التفاصيل البيبلوغرافية
العنوان: The influence of the electrodes spacing of a mapping catheter on the atrial voltage substrate map
المؤلفون: Yuichiro Shiki, Takahiko Nagase, Toshihiro Muramatsu, Sayaka Tanaka, Ritsushi Kato, Kazuo Matsumoto, Shiro Iwanaga, Yoshifumi Ikeda, Hitoshi Mori, Mai Tahara, Koji Goto, So Asano
المصدر: Journal of cardiology. 72(5)
سنة النشر: 2018
مصطلحات موضوعية: Male, medicine.medical_specialty, Substrate mapping, medicine.medical_treatment, Catheter ablation, 030204 cardiovascular system & hematology, 03 medical and health sciences, 0302 clinical medicine, Heart Conduction System, Internal medicine, Atrial Fibrillation, medicine, Humans, Sinus rhythm, 030212 general & internal medicine, Heart Atria, Electrodes, business.industry, Atrial fibrillation, Middle Aged, medicine.disease, Ablation, Catheter, Electrode, Cardiology, Catheter Ablation, Female, Cardiology and Cardiovascular Medicine, business, Electrophysiologic Techniques, Cardiac, Low voltage
الوصف: Detailed substrate mapping is important for catheter ablation. However, the influence of the electrode spacing of the mapping catheter on the substrate map has not been well clarified. The aim of this study was to investigate the influence of the electrode spacing of the mapping catheter on the voltage of the substrate map.Protocol 1: We recorded the local atrial potentials of the left atrium (LA) using the ablation catheter during sinus rhythm in six atrial fibrillation (AF) patients. The voltage of each atrial potential was compared between a close-bipolar (1-2 electrode) recording and wide-bipolar (1-4 electrode) recording. Protocol 2: Two voltage-maps of the LA were constructed separately using a 20-pole circular catheter and 10-pole circular catheter during sinus rhythm in 42 AF patients. The low voltage zone (LVZ) (0.5mV) areas obtained by 2 voltage maps using the 10-pole and 20-pole circular catheters were compared.Protocol 1: The close-bipolar voltage of the local potentials was significantly smaller than that of the wide-bipolar voltages (0.76±0.39mV vs. 0.63±0.41mV, p0.0001). Protocol 2: The size of the LVZ areas identified by the 10-pole and 20-pole catheters was 1.12±1.92cmThe voltage of the local atrial potential using the close-bipolar catheter was significantly smaller than that using the wide-bipolar catheter. Care should be given to the electrode spacing of mapping catheters when analyzing the voltage of the atrial myocardial potentials.
تدمد: 1876-4738
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c8a9be4f675caf0052280d9a0ef5a342Test
https://pubmed.ncbi.nlm.nih.gov/29859827Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....c8a9be4f675caf0052280d9a0ef5a342
قاعدة البيانات: OpenAIRE