دورية أكاديمية

A leak-free head-out plethysmography system to accurately assess lung function in mice.

التفاصيل البيبلوغرافية
العنوان: A leak-free head-out plethysmography system to accurately assess lung function in mice.
المؤلفون: Bruggink, Stephanie, Kentch, Kyle, Kronenfeld, Jason, Renquist, Benjamin J.
المصدر: Journal of Applied Physiology; Jul2022, Vol. 133 Issue 1, p104-118, 15p
مصطلحات موضوعية: PLETHYSMOGRAPHY, HOUSE dust mites, LUNG volume, LUNGS, MICE
مستخلص: Mice are a valuable model for elegant studies of complex, system-dependent diseases, including pulmonary diseases. Current tools to assess lung function in mice are either terminal or lack accuracy. We set out to develop a low-cost, accurate, headout variable-pressure plethysmography system to allow for repeated, nonterminal measurements of lung function in mice. Current head-out plethysmography systems are limited by air leaks that prevent accurate measures of volume and flow. We designed an inflatable cuff that encompasses the mouse’s neck preventing air leak. We wrote corresponding software to collect and analyze the data, remove movement artifacts, and automatically calibrate each dataset. This software calculates volume, inspiratory/expiratory time, breaths per minute, mid-expiratory flow, and end-inspiratory pause. To validate the use, we established that our plethysmography system accurately measured tidal breathing, the bronchoconstrictive response to methacholine, sex- and age-associated changes in breathing, and breathing changes associated with house dust mite sensitization. Our estimates of volume, flow, and timing of breaths are in line with published estimates, we observed dose-dependent decreases in volume and flow in response to methacholine (P < 0.05), increased lung volume, and decreased breathing rate with aging (P < 0.05), and that house dust mite sensitization decreased volume and flow (P < 0.05) while exacerbating the methacholine-induced increase in inspiratory time (P < 0.05). We describe an accurate, sensitive, low-cost, head-out plethysmography system that allows for longitudinal studies of pulmonary disease in mice. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Applied Physiology is the property of American Physiological Society and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:87507587
DOI:10.1152/japplphysiol.00835.2021