دورية أكاديمية

The Silk Vista Baby – The UK experience.

التفاصيل البيبلوغرافية
العنوان: The Silk Vista Baby – The UK experience.
المؤلفون: Bhogal, P, Makalanda, HLD, Wong, K, Keston, P, Downer, J, Du Plessis, JC, Nania, A, Simonato, D, Fuschi, M, Chong, W, O'Reilly, S, Rennie, I
المصدر: Interventional Neuroradiology; Apr2022, Vol. 28 Issue 2, p201-212, 12p
مصطلحات موضوعية: DISSECTING aneurysms, SILK, ANEURYSMS, INFANTS
مصطلحات جغرافية: UNITED Kingdom
مستخلص: Background: The Silk Vista Baby (SVB) flow diverter (FDS) is the only FDS deliverable via a 0.017 inch microcatheter and is specifically designed for the distal vasculature. We sought to evaluate the safety and efficacy of the SVB. Materials and Methods: We performed a retrospective review to identify SVB cases at 4 tertiary neurosurgical centres within the U.K. Clinical, procedural, angiographic and follow-up data were collected. Results: We identified 60 patients (35 female, 58%) of average age 54 ± 10.5 (range 30–72) with 61 aneurysms, 50 (81.9%) located in the anterior circulation. The majority of the aneurysms treated were unruptured (46, 75.4%) and saccular (46, 75.4%). Dome size was 6.2 ± 6.2 mm (range 1–36mm) and parent vessel diameter was 2.3 ± 0.4 mm (range 1.2-3.3 mm). An average number of 1.07 devices were implanted. Coils or other devices were implanted in 14 aneurysms (23.3%). At last angiographic follow-up (n = 55), 7.5 ± 4.2 months post-procedure, 32 aneurysms (57.1%) were graded as RRC I, 7 (12.5%) RRC II, and 17 RRC III (30.4%). Clinical complications, excluding death, were seen in 4 patients (6.8%) including 1 delayed aneurysm rupture and 3 symptomatic ischaemic events. Only one patient had permanent morbidity (mRS 1). 3 patients died during follow-up (5.1%); 2 deaths were related to the aneurysms (3.4%) – one ruptured dissecting MCA aneurysm, and one giant partially thrombosed posterior circulation aneurysm. 93% of patients were mRS ≤ 2 at last follow-up. Conclusion: The SVB has high rates of technical success and an acceptable safety profile. Distal aneurysms may occlude slower due to relative oversizing of the devices. [ABSTRACT FROM AUTHOR]
Copyright of Interventional Neuroradiology is the property of Sage Publications, Ltd. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:15910199
DOI:10.1177/15910199211024061