Reactive atrial-based anti-tachycardia pacing algorithm in cardiovascular implantable electronic devices is safe and feasible without increase in thromboembolic events in patients with a left atrial appendage closure device.

التفاصيل البيبلوغرافية
العنوان: Reactive atrial-based anti-tachycardia pacing algorithm in cardiovascular implantable electronic devices is safe and feasible without increase in thromboembolic events in patients with a left atrial appendage closure device.
المؤلفون: Carter, Cody, Khan, Zeryab, El-Zein, Rayan, Lockhart, Marie, Shah, Ankur, Nemer, David, Tyler, Jaret, Fu, Eugene, Badin, Auroa, Billakanty, Sreedhar R., Amin, Anish K., Chopra, Nagesh
المصدر: International Journal of Arrhythmia; 10/1/2023, Vol. 24 Issue 1, p1-7, 7p
مصطلحات موضوعية: CARDIOVASCULAR disease diagnosis, IMPLANTABLE cardioverter-defibrillators, ELECTRONIC equipment, THROMBOEMBOLISM, COMPUTER algorithms
مستخلص: Background: Reactive atrial-based anti-tachycardia pacing (rATP) in CIED (cardiovascular implantable electronic devices) is effective in atrial fibrillation (AF) suppression. Uninterrupted systemic anticoagulation is recommended when this algorithm is activated to avoid stroke, however, the use of a rATP algorithm in patients with a left atrial appendage (LAA) closure device has not been studied. We assessed the safety and feasibility of rATP algorithm to suppress AF in patients with a LAA closure device over an extended period. Methods: Data from 55 consecutive patients who underwent a Watchman® implant at a tertiary care hospital between September 1, 2015, and January 30, 2020, who also had an in situ Medtronic® CIED (45 with and 10 without rATP capability) were retrospectively reviewed. Results: The 55-patient cohort was 60% male, 77 ± 8 years old, CHA2DS2-VASc score 5 (4–6), HAS-BLED score 3 (3–4), LVEF 53 ± 14%, LA size 4.4 ± 0.7 cm and ventricular pacing burden of 73 (1.4–98.3)%. The CIEDs (20 ICDs and 35 pacemakers) antedated Watchman® implants by 915 ± 725 days. Post-implant, all patients discontinued anticoagulation. Twenty patients in the rhythm-control group with active rATP algorithm displayed no increase in yearly AF burden and were less likely to develop permanent/long-standing persistent AF (p = 0.002) when compared to 35 patients in the rate-control group with CIEDs inactive/incapable of rATP over a ≤ 5-year follow-up. The longest AF episode in the rhythm-control group lasted 204 (19–2520) h. There was no increase in stroke/thromboembolism and a significant reduction in major bleeding noted over ≤ 5 years pre- versus post-implant in the whole cohort (p = 0.005). Conclusion: rATP algorithm use is safe and feasible in patients with a Watchman® device. Patients should be forewarned of a surge in post-Watchman® implant AF burden. [ABSTRACT FROM AUTHOR]
Copyright of International Journal of Arrhythmia is the property of BioMed Central and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)