دورية أكاديمية

Diagnostic accuracy of novel serological biomarkers to detect acute mesenteric ischemia: a systematic review and meta-analysis.

التفاصيل البيبلوغرافية
العنوان: Diagnostic accuracy of novel serological biomarkers to detect acute mesenteric ischemia: a systematic review and meta-analysis.
المؤلفون: Treskes, Nikki, Persoon, Alexandra, van Zanten, Arthur, Persoon, Alexandra M, van Zanten, Arthur R H
المصدر: Internal & Emergency Medicine; Sep2017, Vol. 12 Issue 6, p821-836, 16p
مستخلص: Laparotomy remains the gold standard for diagnosis of acute mesenteric ischemia (AMI), but is often unhelpful or too late due to non-specific clinical and radiological signs. This systematic review and meta-analysis aims to evaluate the diagnostic accuracy of the novel serological biomarkers intestinal fatty acid-binding protein (I-FABP), α-glutathione S-transferase (α-GST), D-lactate, ischemia modified albumin (IMA), and citrulline to detect AMI. A systematic search of electronic databases was performed to identify all published diagnostic accuracy studies on I-FABP, α-GST, D-lactate, IMA, and citrulline. Articles were selected based on pre-defined inclusion and exclusion criteria. Risk of bias and applicability were assessed. Two-by-two contingency tables were constructed to calculate accuracy standards. Summary estimates were computed using random-effects models. The search yielded 1925 papers, 21 were included in the final analysis. Pooled sensitivity and specificity for investigated biomarkers were: I-FABP (Uden); 79.0 (95% CI 66.5-88.5) and 91.3 (87.0-94.6), I-FABP (Osaka); 75.0 (67.9-81.2) and 79.2 (76.2-82.0), D-lactate; 71.7 (58.6-82.5) and 74.2 (69.0-79.0), α-GST; 67.8 (54.2-79.5) and 84.2 (75.3-90.9), IMA; 94.7 (74.0-99.9) and 86.4 (65.1-97.1), respectively. One study investigated accuracy standards for citrulline: sensitivity 39% and specificity 100%. The novel serological biomarkers I-FABP, α-GST, IMA, and citrulline may offer improved diagnostic accuracy of acute mesenteric ischemia; however, further research is required to specify threshold values and accuracy standards for different aetiological forms. [ABSTRACT FROM AUTHOR]
Copyright of Internal & Emergency Medicine is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:18280447
DOI:10.1007/s11739-017-1668-y