Electrocardiogram of a Silver Nanowire Based Dry Electrode: Quantitative Comparison With the Standard Ag/AgCl Gel Electrode

التفاصيل البيبلوغرافية
العنوان: Electrocardiogram of a Silver Nanowire Based Dry Electrode: Quantitative Comparison With the Standard Ag/AgCl Gel Electrode
المؤلفون: Chengyu Liu, Yong Zhu, He Huang, Qin Qin, Shanshan Yao, Jianqing Li
المصدر: IEEE Access, Vol 7, Pp 20789-20800 (2019)
بيانات النشر: IEEE, 2019.
سنة النشر: 2019
مصطلحات موضوعية: 010407 polymers, Materials science, General Computer Science, Gel electrode, Dry electrode, 02 engineering and technology, Silver nanowires, signal quality indices, 01 natural sciences, Silver chloride, chemistry.chemical_compound, Signal quality, ECG discrepancy comparison, 0202 electrical engineering, electronic engineering, information engineering, General Materials Science, General Engineering, heart rate variability analysis, 020206 networking & telecommunications, Baseline drift, 0104 chemical sciences, chemistry, Ecg waveforms, Electrode, lcsh:Electrical engineering. Electronics. Nuclear engineering, ambulatory ECG, lcsh:TK1-9971, Biomedical engineering
الوصف: Novel dry electrodes have promoted the development of wearable electrocardiogram (ECG) that is collected in daily life to monitor the ambulatory activity of heart status. To evaluate the performance of a dry electrode, it is necessary to compare it with the commercial disposable silver/silver chloride (Ag/AgCl) gel electrode. In this paper, a silver nanowire (AgNW)-based dry electrode was fabricated for noninvasive and wearable ECG sensing. Signals from the AgNW electrode and the Ag/AgCl electrode were simultaneously collected in two conditions: sitting and walking. Signal quality was evaluated in terms of ECG morphology, R-peak to R-peak interval, and heart rate variability analysis. Quantitative comparisons showed that the AgNW electrode could collect acceptable ECG waveforms as the Ag/AgCl electrode in both the sitting and walking conditions. However, the baseline drift and waveform distortions existed in the AgNW electrode, likely due to electrode motion. If the skin-electrode contact is improved, the dry electrode can be a promising substitute for the Ag/AgCl electrode.
اللغة: English
تدمد: 2169-3536
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::bec004576010d5c32bf5faf4ee4df730Test
https://ieeexplore.ieee.org/document/8635458Test/
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....bec004576010d5c32bf5faf4ee4df730