دورية أكاديمية

Dynamics of vascular refilling in extended nocturnal hemodialysis.

التفاصيل البيبلوغرافية
العنوان: Dynamics of vascular refilling in extended nocturnal hemodialysis.
المؤلفون: Kron, Susanne, Schneditz, Daniel, Leimbach, Til, Schneider, Johanna, Kron, Joachim
المصدر: Hemodialysis International; Oct2022, Vol. 26 Issue 4, p540-547, 8p
مصطلحات موضوعية: BLOOD volume, INDICATOR dilution, HEMODIALYSIS, DIALYSIS (Chemistry), ULTRAFILTRATION
مستخلص: Introduction: Long dialysis treatments are generally assumed to mitigate the ultrafiltration (UF) induced volume perturbation and to improve vascular refilling because of reduced UF rates and sufficient time for volume re‐equilibration. The time course of vascular refilling was therefore examined during extended nocturnal dialysis. Methods: For each hour of dialysis, vascular refilling volume was calculated from the absolute blood volume changes and UF volume removed. Absolute blood volume was estimated by indicator dilution at the beginning of dialysis and then tracked with a relative blood volume monitor. The refilling fraction was defined as the ratio of refilling volume to UF volume. Findings: Ten stable chronic hemodialysis (HD) patients were studied during extended (7 h) nocturnal treatment sessions. Specific UF rate was 4.8 ± 1.8 ml/kg/h. In the 1 h, refilling volume amounted to only 23% of UF volume. Thereafter, refilling fraction steeply increased and reached maximum values in the 2, 3 and 4 h at about mean 90% (91.5%, 88.7%, and 91.1% respectively). From the 5 h on, refilling volume decreased (5 h 81.3%, 6 h 72.5%, 7 h 70.0% of UF volume). Cumulative refilling reached 73.6% of UF volume after 4 h of treatment time. This did not change during the further course of HD. Cumulative refilling volume showed a strong correlation (r = 0.94; p < 0.001) with UF volume. The ratio of blood volume to extracellular volume (Rbex) was 0.306 ± 0.029 before and slightly but significantly increased to 0.326 ± 0.030 after UF. Discussion In spite of low‐UF rates and extended treatment times, overall refilling fraction reached only 74% and was not different from the refilling fraction observed in regular HD. This value seems to represent a point where UF‐induced volume perturbation is adequately compensated by physiologic control mechanisms. [ABSTRACT FROM AUTHOR]
Copyright of Hemodialysis International is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:14927535
DOI:10.1111/hdi.13029