دورية أكاديمية

Enhancing classification of preterm-term birth using continuous wavelet transform and entropy-based methods of electrohysterogram signals.

التفاصيل البيبلوغرافية
العنوان: Enhancing classification of preterm-term birth using continuous wavelet transform and entropy-based methods of electrohysterogram signals.
المؤلفون: Romero-Morales, Héctor, Muñoz-Montes de Oca, Jenny Noemí, Mora-Martínez, Rodrigo, Mina-Paz, Yecid, Javier Reyes-Lagos, José
المصدر: Frontiers in Endocrinology; 1/10/2023, Vol. 13, p1-11, 11p
مصطلحات موضوعية: WAVELET transforms, PREMATURE labor, CHILDBIRTH, FEATURE selection, CLINICAL medicine
مستخلص: Introduction: Despite vast research, premature birth's electrophysiological mechanisms are not fully understood. Prediction of preterm birth contributes to child survival by providing timely and skilled care to both mother and child. Electrohysterography is an affordable, noninvasive technique that has been highly sensitive in diagnosing preterm labor. This study aimed to choose the more appropriate combination of characteristics, such as electrode channel and bandwidth, as well as those linear, time-frequency, and nonlinear features of the electrohysterogram (EHG) for predicting preterm birth using classifiers. Methods: We analyzed two open-access datasets of 30 minutes of EHG obtained in regular checkups of women around 31 weeks of pregnancy who experienced premature labor (P) and term labor (T). The current approach filtered the raw EHGs in three relevant frequency subbands (0.3-1 Hz, 1-2 Hz, and 2-3Hz). The EHG time series were then segmented to create 120-second windows, from which individual characteristics were calculated. The linear, time-frequency, and nonlinear indices of EHG of each combination (channelfilter) were fed to different classifiers using feature selection techniques. Results: The best performance, i.e., 88.52% accuracy, 83.83% sensitivity, and 93.22% specificity, was obtained in the 2-3 Hz bands using Medium Frequency, Continuous Wavelet Transform (CWT), and entropy-based indices. Interestingly, CWT features were significantly different in all filter-channel combinations. The proposed study uses small samples of EHG signals to diagnose preterm birth accurately, showing their potential application in the clinical environment. Discussion: Our results suggest that CWT and novel entropy-based features of EHG could be suitable descriptors for analyzing and understanding the complex nature of preterm labor mechanisms. [ABSTRACT FROM AUTHOR]
Copyright of Frontiers in Endocrinology is the property of Frontiers Media S.A. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:16642392
DOI:10.3389/fendo.2022.1035615