دورية أكاديمية

Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS).

التفاصيل البيبلوغرافية
العنوان: Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS).
المؤلفون: Einstein, Andrew J., Pascual, Thomas N. B., Mercuri, Mathew, Karthikeyan, Ganesan, Vitola, João V., Mahmarian, John J., Better, Nathan, Bouyoucef, Salah E., Bom, Henry Hee-Seung, Lele, Vikram, Magboo, V. Peter C., Alexánderson, Erick, Allam, Adel H., Al-Mallah, Mouaz H., Flotats, Albert, Jerome, Scott, Kaufmann, Philipp A., Luxenburg, Osnat, Shaw, Leslee J., Underwood, S. Richard
المصدر: European Heart Journal; 7/7/2015, Vol. 36 Issue 26, p1689-1696, 8p, 4 Charts, 1 Graph
مستخلص: Aims: To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiationoptimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results: We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposurewere identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. Conclusion: Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally. [ABSTRACT FROM AUTHOR]
Copyright of European Heart Journal is the property of Oxford University Press / USA and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:0195668X
DOI:10.1093/eurheartj/ehv117