دورية أكاديمية

The usefulness of rapid point-of-care creatinine testing for the prevention of contrast-induced nephropathy in the emergency department.

التفاصيل البيبلوغرافية
العنوان: The usefulness of rapid point-of-care creatinine testing for the prevention of contrast-induced nephropathy in the emergency department.
المؤلفون: Je Sung You, Yong Eun Chung, Jong Woo Park, Woonhyoung Lee, Hye-Jeong Lee, Tae Nyoung Chung, Sung Phil Chung, Incheol Park, Seungho Kim
المصدر: Emergency Medicine Journal (EMJ); Jul2013, Vol. 30 Issue 7, p555-558, 4p, 2 Graphs
مستخلص: Background Renal dysfunction is the most important factor to consider when predicting a patient's risk of developing contrast-induced nephropathy (CIN). Measurement of creatinine (Cr) via rapid point-of-care blood urea nitrogen/creatinine testing (POCT-BUN/Cr) to determine CIN risk could potentially reduce the time required to achieve an accurate diagnosis and to initiate and complete treatment in the emergency department (ED). The aim of our study was to compare the results of POCT-BUN/Cr and reference laboratory tests for BUN and serum Cr. Materials and methods A retrospective analysis of suspected stroke patients who presented between November 2009 and November 2010, and had BUN and Cr levels measured by POCT-BUN/Cr, and the reference laboratory tests performed with the blood sample which was transferred to the central laboratory by an air-shoot system. Two assays were conducted on the whole blood (POCT) and serum (reference) by trained technicians. The time interval from arrival at the ED to reporting of the results was assessed for both assays via a computerised physician order entry system. Results The mean standard deviation (SD) interval from arrival at the ED to reporting of the results was 11.4 (4.9) min for POCT-BUN/Cr and 46.8 (38.5) min for the serum reference laboratory tests (p<0.001). Intra-class correlation coefficient (ICC) analysis demonstrated a high level of agreement (the consistency agreement) between POCT and the serum reference tests for both BUN (ICC=0.914) and Cr (ICC=0.980). Conclusions This study suggests that POCT-BUN/Cr results correlate well with those of serum reference tests in terms of BUN and Cr levels and, in turn, predicting CIN. POCT-BUN/Cr is easily performed with a rapid turnaround time, suggesting its use in the ED may have substantial clinical benefit. [ABSTRACT FROM AUTHOR]
Copyright of Emergency Medicine Journal (EMJ) is the property of BMJ Publishing Group and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:14720205
DOI:10.1136/emermed-2012-201285