Can a penalized-likelihood estimation algorithm be used to reduce the injected dose or the acquisition time in 68Ga-DOTATATE PET/CT studies?

التفاصيل البيبلوغرافية
العنوان: Can a penalized-likelihood estimation algorithm be used to reduce the injected dose or the acquisition time in 68Ga-DOTATATE PET/CT studies?
المؤلفون: Alexandre Chicheportiche, Elinor Goshen, Jeremy Godefroy, Simona Grozinsky-Glasberg, Kira Oleinikov, Amichay Meirovitz, David J. Gross, Simona Ben-Haim
المصدر: EJNMMI Physics, Vol 8, Iss 1, Pp 1-17 (2021)
بيانات النشر: SpringerOpen, 2021.
سنة النشر: 2021
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
مصطلحات موضوعية: Q.Clear reconstruction, Reduced acquisition time or injected dose, Image quality, Visual evaluation, 68Ga-DOTATATE, Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Abstract Background Image quality and quantitative accuracy of positron emission tomography (PET) depend on several factors such as uptake time, scanner characteristics and image reconstruction methods. Ordered subset expectation maximization (OSEM) is considered the gold standard for image reconstruction. Penalized-likelihood estimation (PL) algorithms have been recently developed for PET reconstruction to improve quantitation accuracy while maintaining or even improving image quality. In PL algorithms, a regularization parameter β controls the penalization of relative differences between neighboring pixels and determines image characteristics. In the present study, we aim to compare the performance of Q.Clear (PL algorithm, GE Healthcare) and OSEM (3 iterations, 8 subsets, 6-mm post-processing filter) for 68Ga-DOTATATE (68Ga-DOTA) PET studies, both visually and quantitatively. Thirty consecutive whole-body 68Ga-DOTA studies were included. The data were acquired in list mode and were reconstructed using 3D OSEM and Q.Clear with various values of β and various acquisition times per bed position (bp), thus generating images with reduced injected dose (1.5 min/bp: β = 300–1100; 1.0 min/bp: β = 600–1400 and 0.5 min/bp: β = 800–2200). An additional analysis adding β values up to 1500, 1700 and 3000 for 1.5, 1.0 and 0.5 min/bp, respectively, was performed for a random sample of 8 studies. Evaluation was performed using a phantom and clinical data. Two experienced nuclear medicine physicians blinded to the variables assessed the image quality visually. Results Clinical images reconstructed with Q.Clear, set at 1.5, 1.0 and 0.5 min/bp using β = 1100, 1300 and 3000, respectively, resulted in images with noise equivalence to 3D OSEM (1.5 min/bp) with a mean increase in SUVmax of 14%, 13% and 4%, an increase in SNR of 30%, 24% and 10%, and an increase in SBR of 13%, 13% and 2%. Visual assessment yielded similar results for β values of 1100–1400 and 1300–1600 for 1.5 and 1.0 min/bp, respectively, although for 0.5 min/bp there was no significant improvement compared to OSEM. Conclusion 68Ga-DOTA reconstructions with Q.Clear, 1.5 and 1.0 min/bp, resulted in increased tumor SUVmax and in improved SNR and SBR at a similar level of noise compared to 3D OSEM. Q.Clear with β = 1300–1600 enables one-third reduction of acquisition time or injected dose, with similar image quality compared to 3D OSEM.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2197-7364
العلاقة: https://doaj.org/toc/2197-7364Test
DOI: 10.1186/s40658-021-00359-6
الوصول الحر: https://doaj.org/article/6089a5716c444cb6839e7e39b6416f1fTest
رقم الانضمام: edsdoj.6089a5716c444cb6839e7e39b6416f1f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21977364
DOI:10.1186/s40658-021-00359-6