دورية أكاديمية

System evaluation of automated production and inhalation of 15O-labeled gaseous radiopharmaceuticals for the rapid 15O-oxygen PET examinations

التفاصيل البيبلوغرافية
العنوان: System evaluation of automated production and inhalation of 15O-labeled gaseous radiopharmaceuticals for the rapid 15O-oxygen PET examinations
المؤلفون: Satoshi Iguchi, Tetsuaki Moriguchi, Makoto Yamazaki, Yuki Hori, Kazuhiro Koshino, Kazunori Toyoda, Jarmo Teuho, Saeka Shimochi, Yusuke Terakawa, Tetsuya Fukuda, Jun C. Takahashi, Jyoji Nakagawara, Shigehiko Kanaya, Hidehiro Iida
المصدر: EJNMMI Physics, Vol 5, Iss 1, Pp 1-21 (2018)
بيانات النشر: SpringerOpen, 2018.
سنة النشر: 2018
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
مصطلحات موضوعية: 15O-labeled oxygen (15O2), 15O-labeled carbon dioxide (C15O2), PET, Oxygen extraction fraction, Cerebral metabolic rate of oxygen, Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Abstract Background 15O-oxygen inhalation PET is unique in its ability to provide fundamental information regarding cerebral hemodynamics and energy metabolism in man. However, the use of 15O-oxygen has been limited in a clinical environment largely attributed to logistical complexity, in relation to a long study period, and the need to produce and inhale three sets of radiopharmaceuticals. Despite the recent works that enabled shortening of the PET examination period, radiopharmaceutical production has still been a limiting factor. This study was aimed to evaluate a recently developed radiosynthesis/inhalation system that automatically supplies a series of 15O-labeled gaseous radiopharmaceuticals of C15O, 15O2, and C15O2 at short intervals. Methods The system consists of a radiosynthesizer which produces C15O, 15O2, and C15O2; an inhalation controller; and an inhalation/scavenging unit. All three parts are controlled by a common sequencer, enabling automated production and inhalation at intervals less than 4.5 min. The gas inhalation/scavenging unit controls to sequentially supply of qualified radiopharmaceuticals at given radioactivity for given periods at given intervals. The unit also scavenges effectively the non-inhaled radioactive gases. Performance and reproducibility are evaluated. Results Using an 15O-dedicated cyclotron with deuteron of 3.5 MeV at 40 μA, C15O, 15O2, and C15O2 were sequentially produced at a constant rate of 1400, 2400, and 2000 MBq/min, respectively. Each of radiopharmaceuticals were stably inhaled at
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2197-7364
العلاقة: http://link.springer.com/article/10.1186/s40658-018-0236-5Test; https://doaj.org/toc/2197-7364Test
DOI: 10.1186/s40658-018-0236-5
الوصول الحر: https://doaj.org/article/774cd65ebdfe4e318d0515171d5a168bTest
رقم الانضمام: edsdoj.774cd65ebdfe4e318d0515171d5a168b
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21977364
DOI:10.1186/s40658-018-0236-5