دورية أكاديمية

Technical Evaluation of the COBAS EGFR Semiquantitative Index (SQI) for Plasma cfDNA Testing in NSCLC Patients with EGFR Exon 19 Deletions.

التفاصيل البيبلوغرافية
العنوان: Technical Evaluation of the COBAS EGFR Semiquantitative Index (SQI) for Plasma cfDNA Testing in NSCLC Patients with EGFR Exon 19 Deletions.
المؤلفون: González de Aledo-Castillo, José Manuel, Serhir-Sgheiri, Samira, Calbet-Llopart, Neus, Arcocha, Ainara, Jares, Pedro, Reguart, Noemí, Puig-Butillé, Joan Antón
المصدر: Diagnostics (2075-4418); Aug2021, Vol. 11 Issue 8, p1319, 1p
مصطلحات موضوعية: EPIDERMAL growth factor receptors, CELL-free DNA, PROTEIN-tyrosine kinase inhibitors, NON-small-cell lung carcinoma
مستخلص: The cobas® EGFR Test provides a semiquantitative index (SQI) that reflects the proportion of mutated versus wild-type copies of the EGFR gene in plasma. The significance of SQI as an indirect measure of the variant allele frequency (VAF) or mutated copies/mL remains unclear. The aim of this study was to evaluate the correlation of SQI with the VAF and the number of mutated copies/mL obtained by a digital droplet PCR (ddPCR) test in NSCLC samples. The study included 118 plasma samples from a retrospective cohort of 25 stage IV adenocarcinoma patients with EGFR exon 19 deletions (Ex19Del), obtained before and during tyrosine kinase inhibitor (TKI) treatment. Both SQI and VAF and SQI and mutated copies/mL showed the same significant correlation (r2 = 0.79, p < 0.00001) across the whole study cohort. We found better correlation in samples collected at the baseline between SQI and VAF (r2 = 0.94, p < 0.00001) and SQI and mutated copies/mL (r2 = 0.97, p < 0.00001) compared to samples collected during TKI treatment: r2 = 0.76; p < 0.00001 for SQI and VAF and r2 = 0.75; p < 0.00001 for SQI and mutated copies/mL. The study indicates that SQI is a robust quantitative indirect measure of VAF and the number of mutated copies/mL in plasma from patients with an EGFR Ex19Del mutation. Further studies are desirable to assess the SQI cut-off values related to the clinical status of the patient. [ABSTRACT FROM AUTHOR]
Copyright of Diagnostics (2075-4418) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:20754418
DOI:10.3390/diagnostics11081319