Coming of age: the artificial pancreas for type 1 diabetes

التفاصيل البيبلوغرافية
العنوان: Coming of age: the artificial pancreas for type 1 diabetes
المؤلفون: Hood Thabit, Roman Hovorka
المساهمون: Hovorka, Roman [0000-0003-2901-461X], Apollo - University of Cambridge Repository
المصدر: Diabetologia
بيانات النشر: Springer Nature
مصطلحات موضوعية: Blood Glucose, Pancreas, Artificial, Insulin pump, Closed-loop system, medicine.medical_specialty, Glucose control, medicine.medical_treatment, Endocrinology, Diabetes and Metabolism, Continuous glucose monitor, Control algorithm, Insulin delivery, Artificial pancreas, 030209 endocrinology & metabolism, Review, 03 medical and health sciences, 0302 clinical medicine, Internal medicine, Diabetes mellitus, medicine, Internal Medicine, Humans, Insulin, Tight glucose control, 030212 general & internal medicine, Intensive care medicine, Type 1 diabetes, business.industry, medicine.disease, 3. Good health, Diabetes Mellitus, Type 1, Endocrinology, business, Algorithms
الوصف: The artificial pancreas (closed-loop system) addresses the unmet clinical need for improved glucose control whilst reducing the burden of diabetes self-care in type 1 diabetes. Glucose-responsive insulin delivery above and below a preset insulin amount informed by sensor glucose readings differentiates closed-loop systems from conventional, threshold-suspend and predictive-suspend insulin pump therapy. Insulin requirements in type 1 diabetes can vary between one-third-threefold on a daily basis. Closed-loop systems accommodate these variations and mitigate the risk of hypoglycaemia associated with tight glucose control. In this review we focus on the progress being made in the development and evaluation of closed-loop systems in outpatient settings. Randomised transitional studies have shown feasibility and efficacy of closed-loop systems under supervision or remote monitoring. Closed-loop application during free-living, unsupervised conditions by children, adolescents and adults compared with sensor-augmented pumps have shown improved glucose outcomes, reduced hypoglycaemia and positive user acceptance. Innovative approaches to enhance closed-loop performance are discussed and we also present the outlook and strategies used to ease clinical adoption of closed-loop systems.
وصف الملف: application/pdf
اللغة: English
تدمد: 0012-186X
DOI: 10.1007/s00125-016-4022-4
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::48b338a827f44c502c8d0cec7ed99a43Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....48b338a827f44c502c8d0cec7ed99a43
قاعدة البيانات: OpenAIRE
الوصف
تدمد:0012186X
DOI:10.1007/s00125-016-4022-4