HbA1c determination from HemaSpot™ blood collection devices: comparison of home prepared dried blood spots with standard venous blood analysis

التفاصيل البيبلوغرافية
العنوان: HbA1c determination from HemaSpot™ blood collection devices: comparison of home prepared dried blood spots with standard venous blood analysis
المؤلفون: C. F. Fowler, M. Van Drimmelen, Jenny Hall, Sandra MacRury, Roger W. Humphry, F. Barrett
المصدر: Diabetic Medicine
بيانات النشر: John Wiley and Sons Inc., 2019.
سنة النشر: 2019
مصطلحات موضوعية: Adult, Male, medicine.medical_specialty, Endocrinology, Diabetes and Metabolism, 030209 endocrinology & metabolism, Young Adult, 03 medical and health sciences, 0302 clinical medicine, Endocrinology, Research: Care Delivery, Diabetes mellitus, Internal Medicine, Humans, Medicine, 030212 general & internal medicine, Dried blood, Care Delivery, Chromatography, High Pressure Liquid, Research Articles, Aged, Aged, 80 and over, Glycated Hemoglobin, Blood Specimen Collection, Spots, business.industry, Clinical performance, Reproducibility of Results, Blood collection, Venous blood, Middle Aged, Patient Acceptance of Health Care, medicine.disease, Dried blood spot, Diabetes Mellitus, Type 1, Self-Testing, Diabetes Mellitus, Type 2, Emergency medicine, Female, Dried Blood Spot Testing, Sample collection, business, Blood Chemical Analysis
الوصف: Aim To assess the clinical performance and patient acceptance of HemaSpot™ blood collection devices as an alternative blood collection method. Methods Adult men and women with any type of diabetes, routinely carrying out self‐monitoring of blood glucose were recruited (n = 128). Participants provided a venous blood sample and prepared two HemaSpot dried blood spots, one at clinics and one at home. HbA1c analysis was by Tosoh G8 high‐performance liquid chromatography. Participants also completed a questionnaire. Results Strong linear relationships been HbA1c levels in dried blood spots and venous blood were observed and a linear model was fitted to the data. Time between dried blood spot preparation and testing did not impact the model. Participants were accepting of the approach: 69.2% would use this system if available and 60.7% would be more likely to use this system than going to their general practitioner. Conclusions The combination of a robust desiccating dried blood spot device, home sample preparation and return by post produces HbA1c data that support the use of a time‐independent linear calibration of dried blood spot to venous blood HbA1c. A robust remote sample collection service would be valuable to people living with diabetes in urban areas who are working or house‐bound as well as those living in remote or rural locations.
What's new? HbA1c determination from dried blood spots has been reported but results have been affected by stability issues, requiring methodologies which have included extended drying periods, and storage at low temperatures or for a limited period of time.HbA1c levels determined from HemaSpot blood collection devices show a strong correlation with venous HbA1c results, with the potential for calibration against the venous method used.Patient acceptance of the blood collection method was high, with 61.7% of participants indicating that they would be more likely to have their testing carried out if this method of blood collection was available.By providing patients with an opportunity to increase compliance with regular HbA1c testing, the use of venous calibrated HbA1c determination from HemaSpot blood collection devices provides the potential for improved glycaemic control.
اللغة: English
تدمد: 1464-5491
0742-3071
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::618fd117459958a5ca9dc23ed6709fbdTest
http://europepmc.org/articles/PMC7496699Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....618fd117459958a5ca9dc23ed6709fbd
قاعدة البيانات: OpenAIRE