دورية أكاديمية

Case series of a hybrid closed-loop system used in pregnancies in clinical practice.

التفاصيل البيبلوغرافية
العنوان: Case series of a hybrid closed-loop system used in pregnancies in clinical practice.
المؤلفون: Polsky, Sarit, Akturk, Halis K.
المصدر: Diabetes/Metabolism Research & Reviews; Mar2020, Vol. 36 Issue 3, p1-9, 9p
مصطلحات موضوعية: CLOSED loop systems, TYPE 1 diabetes, GLYCEMIC index, PREGNANCY, DIABETES in women, INSULIN pumps
مستخلص: Background: Hybrid closed-loop (HCL) therapy is rarely studied in pregnancy. We present three cases of women with type 1 diabetes who used the Medtronic 670G HCL system for most or all of gestation.Methods: The Medtronic 670G system has a manual mode (no automated insulin delivery) and an auto mode (AM, HCL therapy). Women in this case series used AM off-label in gestation.Results: Case 1 started HCL therapy in the second trimester, her sensor glucose time spent <3.9 and >10 mmol/L improved thereafter. Case 1 had average sensor glucose (ASG) levels of 6.4 ± 2.4 mmol/L in the first trimester, 7.0 ± 2.7 mmol/L in the second trimester before HCL use, 7.1 ± 2.1 mmol/L in the second trimester after HCL use, and 6.8 ± 1.9 mmol/L in the third trimester. Case 1 continued AM during operative delivery and post-partum. Cases 2 and 3 used HCL therapy throughout gestation but with inconsistent time in AM. When they increased time in AM their glycaemic indices improved. Case 2 had ASG of 9.5 ± 3.4, 8.6 ± 2.9, and 7.9 ± 2.5 mmol/L in the first through third trimesters, respectively. Case 3 had ASG of 11.1 ± 4.8 and 3.9 to 10 mmol/L in the first and second trimesters, respectively. Case 2 continued HCL therapy post-partum, Case 3 did not.Conclusions: CareLink® Clinical Software only reports the non-pregnant time in range. Nonetheless, this represents the first report of HCL therapy in pregnancy with a system approved by the Food and Drug Administration in non-pregnant populations. [ABSTRACT FROM AUTHOR]
Copyright of Diabetes/Metabolism Research & Reviews is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:15207552
DOI:10.1002/dmrr.3248