دورية أكاديمية

Intra- and inter-reader reproducibility in quantitative coronary plaque analysis on coronary computed tomography angiography.

التفاصيل البيبلوغرافية
العنوان: Intra- and inter-reader reproducibility in quantitative coronary plaque analysis on coronary computed tomography angiography.
المؤلفون: Quintana, Raymundo A., von Knebel Doeberitz, Philipp, Vatsa, Nishant, Liu, Chang, Ko, Yi-An, De Cecco, Carlo N., van Assen, Marly, Quyyumi, Arshed A.
المصدر: Current Problems in Cardiology; Jul2024, Vol. 49 Issue 7, pN.PAG-N.PAG, 1p
مستخلص: Coronary artery plaque burden, low attenuation non-calcified plaque (LAP), and pericoronary adipose tissue (PCAT) on coronary CT angiography (CCTA), have been linked to future cardiac events. The purpose of this study was to evaluate intra- and inter reader reproducibility in the quantification of coronary plaque burden and its characteristics using an artificial intelligence-enhanced semi-automated software. A total of 10 women and 6 men, aged 52 (IQR 49-58) underwent CCTA using a Siemens Somatom Force, Somatom Definition AS and Somatom Definition Flash scanners. Two expert readers utilized dedicated semi-automatic software (vascuCAP, Elucid Bioimaging, Wenham, MA) to assess calcified plaque, low attenuation plaque and PCAT. Readers were blinded to all clinical information and repeated their analysis at 6 weeks in random order to minimize recall bias. Data analysis was performed on the right and left coronary arteries. Intra- and inter-reader reproducibility was compared using Pearson correlation coefficient, while absolute values between analyses and readers were compared with paired non-parametric tests. This is a sub-study of the Specialized Center of Research Excellence (SCORE) clinical trial (5U54AG062334). A total of 64 vessels from 16 patients were analyzed. Intra-reader Pearson correlation coefficients for calcified plaque volume, LAP volume and PCAT volumes were 0.96, 0.99 and 0.92 for reader 1 and 0.94, 0.94 and 0.95 for reader 2, respectively, (all p < 0.0001). Inter-reader Pearson correlation coefficients for calcified plaque volume, LAP and PCAT volumes were 0.92, 0.96 and 0.78, and 0.99, 0.99 and 0.93 on the second analyses, all had a p value <0.0001. There was no significant bias on the corresponding Bland–Altman analyses. Volume measurement of coronary plaque burden and PCAT volume can be performed with high intra- and inter-reader agreement. [ABSTRACT FROM AUTHOR]
Copyright of Current Problems in Cardiology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:01462806
DOI:10.1016/j.cpcardiol.2024.102585