Safety of ergot stress echocardiography for non-invasive detection of coronary vasospasm

التفاصيل البيبلوغرافية
العنوان: Safety of ergot stress echocardiography for non-invasive detection of coronary vasospasm
المؤلفون: Olaf Rodriguez, Bruno Ghelarducci, Patrizia Landi, Eugenio Picano, Albert Varga, Attila Pálinkás, Ana Diordjevic-Dikic
المصدر: Coronary artery disease. 12(8)
سنة النشر: 2002
مصطلحات موضوعية: Male, medicine.medical_specialty, Cath lab, medicine.medical_treatment, Stress testing, Coronary Vasospasm, Ventricular tachycardia, Internal medicine, Stress Echocardiography, Medicine, Humans, Ergometrine, cardiovascular diseases, Ergonovine, Cardiac catheterization, Retrospective Studies, business.industry, General Medicine, Middle Aged, medicine.disease, Anesthesia, Coronary vasospasm, Cardiology, Female, Safety, Cardiology and Cardiovascular Medicine, business, medicine.drug, Echocardiography, Stress
الوصف: Background The safety of ergonovine/ergometrine stress testing for coronary vasospasm when performed outside the cardiac catheterization laboratory (cath lab) has been questioned vigorously. Aim To assess the tolerability and safety of ergonovine/ergometrine stress testing performed in the echocardiographic laboratory (echo lab). Methods We retrospectively reviewed the data prospectively collected in the echo lab of the Institute of Clinical Physiology from 1 January 1985 to 1 June 2000, from 587 tests performed on 573 patients (either ergonovine or ergometrine stress echocardiography testing). By selection, all patients had a history of chest pain, consistent with vasospastic angina, negative exercise stress testing or stress echocardiography (with dipyridamole, dobutamine or exercise), and normal or near normal resting left ventricular function. Ergonovine or ergometrine maleate was injected up to a total cumulative dosage of 0.35 mg, under continuous 12-lead electrocardiographic and two-dimensional echocardiographic monitoring. Results There were no deaths, myocardial infarctions, ventricular fibrillations or third degree AV blocks. One patient had non-sustained ventricular tachycardia associated with transient ST segment elevation 30 min after the test. Three patients had second degree AV block associated with a positive echocardiography test that was promptly reversed by nitrates administration. Transient regional myocardial dysfunction occurred in 79 patients (13%). Limiting ischaemia-independent side effects were present in 17 patients (3%): hypotension in one, arterial hypertension in five, non-sustained ventricular tachycardia in two and nausea or vomiting in ten. The test was well tolerated and echocardiograms were interpretable in 97% of the tests performed. Conclusion Pharmacological stress echocardiography with either ergonovine or ergometrine is well tolerated and can be performed with relatively low risk in the echo lab in properly selected patients in whom coronary vasospasm is suspected.
تدمد: 0954-6928
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::54f8c58f8930a4f3a03a94a9367fc123Test
https://pubmed.ncbi.nlm.nih.gov/11811330Test
رقم الانضمام: edsair.doi.dedup.....54f8c58f8930a4f3a03a94a9367fc123
قاعدة البيانات: OpenAIRE