دورية أكاديمية

Effect of wearing different types of face masks during dynamic and isometric resistance training on intraocular pressure.

التفاصيل البيبلوغرافية
العنوان: Effect of wearing different types of face masks during dynamic and isometric resistance training on intraocular pressure.
المؤلفون: Vera, Jesús, Redondo, Beatriz, Koulieris, George-Alex, Jiménez, Raimundo, García-Ramos, Amador
المصدر: Clinical & Experimental Optometry; Jul2023, Vol. 106 Issue 5, p503-508, 6p
مصطلحات موضوعية: RESISTANCE training, MEDICAL masks, SARS-CoV-2, INTRAOCULAR pressure, ISOMETRIC exercise
مستخلص: The use of face masks has demonstrated to be an effective strategy to prevent transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Wearing face masks, mainly Filtering Face Piece 2 (FFP2) masks, during exercise practice has demonstrated to affect several physiological measures. This study was aimed at assessing the intraocular pressure (IOP) behaviour during the execution of the dynamic and isometric biceps-curl exercise with a surgical and FFP2 face mask. Twenty two physically active young adults performed sets of 10 repetitions against the 10-RM (repetition maximum) load and 1-minute isometric effort against a load 15% lower than the 10-RM load with the FFP2 and surgical mask and without any mask. A total of six exercise sets (3 experimental conditions [FFP2, surgical and control] × 2 exercise modalities) were performed. A rebound tonometer was used to measure IOP before, during (10 measurements), and after (30-seconds of passive recovery) each training set. At rest, there were not statistically significant IOP differences (p = 0.222). During dynamic exercise, there was a progressive IOP rise (p < 0.001), and a higher IOP response with the FFP2 than without the mask (corrected p-value = 0.003). For the isometric exercise, there was a greater IOP response as a function of accumulated effort (p < 0.001), which was dependent of the face mask used (FFP2> surgical>control; corrected p-values< 0.01). The FFP2 masks cause a heightened IOP response during the execution of dynamic and isometric biceps-curl exercise, suggesting that, when possible, glaucoma patients should limit the use of FFP2 masks during resistance training. [ABSTRACT FROM AUTHOR]
Copyright of Clinical & Experimental Optometry is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:08164622
DOI:10.1080/08164622.2022.2054315