Evaluation of automated immunoassays for 25(OH)-vitamin D determination in different critical populations before and after standardization of the assays

التفاصيل البيبلوغرافية
العنوان: Evaluation of automated immunoassays for 25(OH)-vitamin D determination in different critical populations before and after standardization of the assays
المؤلفون: Caroline Le Goff, Stéphanie Peeters, Pierre Delanaye, Romy Gadisseur, Jean-Claude Souberbielle, Yannick Crine, Etienne Cavalier, Pierre Lukas, Agnès Carlisi
المصدر: Clinica chimica acta; international journal of clinical chemistry. 431
سنة النشر: 2013
مصطلحات موضوعية: Adult, Clinical Biochemistry, Population, Analytical chemistry, Biochemistry, 3rd trimester, Mass Spectrometry, Matrix (chemical analysis), Automation, Pregnancy, Renal Dialysis, medicine, Vitamin D and neurology, Humans, Critical populations, education, Chromatography, High Pressure Liquid, Immunoassay, education.field_of_study, Chromatography, medicine.diagnostic_test, business.industry, Hydroxycholecalciferols, Vitamin D-Binding Protein, Biochemistry (medical), Reproducibility of Results, General Medicine, Reference Standards, Serum samples, Clinical Practice, Calibration, Osteoporosis, Female, business
الوصف: Standardization of immunoassays for 25(OH)-vitamin D determination is a major problem in clinical practice. A worldwide standardization program has started to address this and will reduce the bias observed between immunoassays. We aimed to calibrate 5 immunoassays on a LC-MS/MS traceable to the SRM 2972 and the ID-LC-MS/MS 25(OH)D Reference Method Procedure to see if the re-standardization would be efficient in a population of 3rd trimester pregnant women (PW), hemodialysis (HD) and osteoporosis (OP) patient.184 serum samples (25(OH)D: 8.4-87 ng/ml) were selected to calibrate the immunoassays (Abbott-Architect, Roche-Elecsys, DiaSorin-Liaison, Siemens-Centaur and IDS-iSYS). Chromsystems MassChrom method was used as the referenced. Serum obtained in 34 PW, 25 HD and 34 OP patients were used as comparatives.After adjusting to LC-MS/MS, immunoassays had regression slopes nearly identical to 1.0 with intercepts0.5 ng/ml. However, in special populations, a systematic bias was still observed, except for iSYS.Re-standardization of 25(OH)D immunoassay will globally improve the differences. However, patients with a different serum matrix will still present significantly different results when they will be run with different methods. For those patients, the LC-MS/MS method seems to be the method of choice, even if some immunoassays are less influenced than others.
تدمد: 1873-3492
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5e99343468f4261e888b4b6ea2507bdaTest
https://pubmed.ncbi.nlm.nih.gov/24508999Test
رقم الانضمام: edsair.doi.dedup.....5e99343468f4261e888b4b6ea2507bda
قاعدة البيانات: OpenAIRE