دورية أكاديمية

MIPAS IMK/IAA CFC-11 (CCl3F) and CFC-12 (CCl2F2) Measurements: Accuracy, Precision and Long-Term Stability

التفاصيل البيبلوغرافية
العنوان: MIPAS IMK/IAA CFC-11 (CCl3F) and CFC-12 (CCl2F2) Measurements: Accuracy, Precision and Long-Term Stability
المؤلفون: Eckert, E., Laeng, A., Lossow, S., Kellmann, S., Stiller, G., Clarmann, T. von, Glatthor, N., Hopfner, M., Kiefer, M., Oelhaf, H., Bernath, P. F.
المصدر: Chemistry & Biochemistry Faculty Publications
بيانات النشر: ODU Digital Commons
سنة النشر: 2016
المجموعة: Old Dominion University: ODU Digital Commons
مصطلحات موضوعية: Atmospheric sounding mipas, Limb emission spectra, Michelson, Interferometer, Retrieval algorithm, Vertical profiles, STR, Measurements, Ozone loss, Ilas- II, Validation, Spectrometer, Atmospheric Sciences, Chemistry, Physics
الوصف: Profiles of CFC-11 (CCl3F) and CFC-12 (CCl2F2) of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) aboard the European satellite Envisat have been retrieved from versions MIPAS/4.61 to MI-PAS/4.62 and MIPAS/5.02 to MIPAS/5.06 level-1b data using the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute of Meteorology and Climate Research (IMK) and Consejo Superior de Investigaciones Cientificas (CSIC), Instituto de Astrofisica de Andalucia (IAA). These profiles have been compared to measurements taken by the balloon-borne cryosampler, Mark IV (MkIV) and MIPAS-Balloon (MIPAS-B), the airborne MIPAS-STRatospheric aircraft (MIPAS-STR), the satellite-borne Atmospheric Chemistry Experiment Fourier transform spectrometer (ACE-FTS) and the High Resolution Dynamic Limb Sounder (HIRDLS), as well as the ground-based Halocarbon and other Atmospheric Trace Species (HATS) network for the reduced spectral resolution period (RR: January 2005-April 2012) of MIPAS. ACE-FTS, MkIV and HATS also provide measurements during the high spectral resolution period (full resolution, FR: July 2002-March 2004) and were used to validate MIPAS CFC-11 and CFC-12 products during that time, as well as profiles from the Improved Limb Atmospheric Spectrometer, ILAS-II. In general, we find that MIPAS shows slightly higher values for CFC-11 at the lower end of the profiles (below ~ 15 km) and in a comparison of HATS ground-based data and MIPAS measurements at 3 km below the tropopause. Differences range from approximately 10 to 50 pptv (~ 5-20 %) during the RR period. In general, differences are slightly smaller for the FR period. An indication of a slight high bias at the lower end of the profile exists for CFC-12 as well, but this bias is far less pronounced than for CFC-11 and is not as obvious in the relative differences between MIPAS and any of the comparison instruments. Differences at the lower end of the profile (below ~15 km) and in the comparison of HATS and MIPAS measurements taken at 3 ...
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: unknown
العلاقة: https://digitalcommons.odu.edu/chemistry_fac_pubs/12Test; https://digitalcommons.odu.edu/context/chemistry_fac_pubs/article/1012/viewcontent/Eckert_2016_MIPAS_IMK_IAA_CFC_11.pdfTest
DOI: 10.5194/amt-9-3355-2016
الإتاحة: https://doi.org/10.5194/amt-9-3355-2016Test
https://digitalcommons.odu.edu/chemistry_fac_pubs/12Test
https://digitalcommons.odu.edu/context/chemistry_fac_pubs/article/1012/viewcontent/Eckert_2016_MIPAS_IMK_IAA_CFC_11.pdfTest
رقم الانضمام: edsbas.60DE4AF4
قاعدة البيانات: BASE