دورية أكاديمية

Rapid and Biosecure Diagnostic Test for Tuberculosis.

التفاصيل البيبلوغرافية
العنوان: Rapid and Biosecure Diagnostic Test for Tuberculosis.
المؤلفون: Garberi, Juan, Labrador, Jorge, Garberi, Federico, Peneipil, Julián, Garberi, Miguel, Scigliano, Luis, Troncoso, Alcides
المصدر: Cell Biochemistry & Biophysics; Mar2013, Vol. 65 Issue 2, p173-179, 7p
مستخلص: Early and rapid detection of the causative organism is necessary in tuberculosis. We present here an integrated and dedicated molecular biology system for tuberculosis diagnosis. One hundred and eighty-nine (189) biologic specimens from patients strongly suspected by clinical parameters of tuberculosis were studied by Ziehl-Neelsen staining, cultivation on a solid medium, and by a balanced heminested fluorometric PCR system (Orange G3TB) that preserves worker safety and produces a rather pure material free of potential inhibitors. DNA amplification was carried out in a low cost using a tuberculosis thermocycler-fluorometer. The double stranded DNA produced is fluorometrically detected. The whole reaction is carried out in one single tube which is never opened after adding the processed sample, thus minimizing the risk of cross contamination with amplicons. The assay is able to detect 30 bacilli/ml of sample having a 99.8 % inter-assay coefficient of variation. PCR was positive in 36 (18.9 %) tested samples (33 of them were smear-negative). In our study, it yields a preliminary overall sensitivity of 97.4 %. In addition, its overall specificity is 98.7 %. The total run time of the test is 4 h with two and a half real working hours. All PCR-positive samples also had a positive result by microbiological culture and clinical criteria. The results obtained showed that it could be a very useful tool to increase efficiency in detecting the tuberculosis disease in low bacillus inoculum samples. Furthermore, its low cost and friendly usage make it feasible to be used in regions with poor development. [ABSTRACT FROM AUTHOR]
Copyright of Cell Biochemistry & Biophysics is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:10859195
DOI:10.1007/s12013-012-9413-7