Bone Assessment after Total Knee Arthroplasty by Dual-Energy X-ray Absorptiometry: Analysis Protocol and Reproducibility

التفاصيل البيبلوغرافية
العنوان: Bone Assessment after Total Knee Arthroplasty by Dual-Energy X-ray Absorptiometry: Analysis Protocol and Reproducibility
المؤلفون: E. C. Marinoni, Marco Bigoni, Sergio Ortolani, Carlo Trevisan, Matteo Denti
المساهمون: Trevisan, C, Bigoni, M, Denti, M, Marinoni, E, Ortolani, S
المصدر: Calcified Tissue International. 62:359-361
بيانات النشر: Springer Science and Business Media LLC, 1998.
سنة النشر: 1998
مصطلحات موضوعية: Male, medicine.medical_specialty, Bone density, Endocrinology, Diabetes and Metabolism, Reproducibility of Result, endoprosthesi, bone strength, densitometry, total knee replacement, Aged, Prosthesis Design, Endocrinology, Bone Density, medicine, Orthopedics and Sports Medicine, Femur, human, Densitometry, X-Ray, Tibia, Arthroplasty, Replacement, Knee, reproducibility, Mineral, Dual-energy X-ray absorptiometry, clinical article, dual energy X ray absorptiometry, Reproducibility, medicine.diagnostic_test, business.industry, adult, article, clinical trial, Middle Aged, aged, female, priority journal, bone mineralization, Orthopedic surgery, diagnostic accuracy, diagnostic value, Implant, Radiology, Nuclear medicine, business, Densitometry, clinical protocol, Bone and Bone
الوصف: Bone quality is important for the success of joint prostheses implantation, and the assessment of bone density after total knee arthroplasty by means of dual-energy X-ray absorptiometry may be useful for monitoring implant stability. The aim of this study is to suggest a validated analysis protocol for the assessment of bone status after total knee arthroplasty. A dedicated densitometric analysis protocol of five regions of interest was designed, and 10 subjects who had received an uncemented knee prosthesis (8 females and 2 males, aged 55–74 years) underwent three consecutive scans in posteroanterior and lateral projections, with repositioning after each scan to test the suitability and reproducibility of the protocol. The reproducibility of the measurement of bone mineral content and density in the femoral and tibial regions ranged, respectively, from 2.1% to 4.1%, from 0.9% to 2.6% for the posteroanterior scans, and from 2.7% to 5.6% and from 2.3% to 4.7% for the lateral scans, depending on the considered region. Our results confirm that the suggested protocol allows precise assessment of bone mineral content and density, and that dual-energy X-ray absorptiometry is reliable for the evaluation of bone mass around prosthetic implants.
تدمد: 1432-0827
0171-967X
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::583cb3dcfe5f01e5d9ca65162eaae24dTest
https://doi.org/10.1007/s002239900444Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....583cb3dcfe5f01e5d9ca65162eaae24d
قاعدة البيانات: OpenAIRE