دورية أكاديمية

Non-Invasive Quantitative Approximation of Intracranial Pressure in Pediatric Idiopathic Intracranial Hypertension Based on Point-of-Care Ultrasound of the Optic Nerve Sheath Diameter.

التفاصيل البيبلوغرافية
العنوان: Non-Invasive Quantitative Approximation of Intracranial Pressure in Pediatric Idiopathic Intracranial Hypertension Based on Point-of-Care Ultrasound of the Optic Nerve Sheath Diameter.
المؤلفون: Kerscher, Susanne Regina, Zipfel, Julian, Bevot, Andrea, Sollmann, Nico, Haas-Lude, Karin, Tellermann, Jonas, Schuhmann, Martin Ulrich
المصدر: Brain Sciences (2076-3425); Jan2024, Vol. 14 Issue 1, p32, 11p
مصطلحات موضوعية: INTRACRANIAL hypertension, OPTIC nerve, INTRACRANIAL pressure, ULTRASONIC imaging, POINT-of-care testing
مستخلص: Background: To investigate whether ultrasound-based optic nerve sheath diameter (US-ONSD) is a reliable measure to follow up children with idiopathic intracranial hypertension (IIH). In addition, to analyze the inter- and intra-individual relationships between US-ONSD and intracranial pressure (ICP), and to investigate whether an individualized mathematical regression equation obtained from two paired US-ONSD/ICP values can be used to approximate ICP from US-ONSD values. Methods: 159 US examinations and 53 invasive ICP measures via lumbar puncture (LP) were performed in 28 children with IIH. US-ONSD was measured using a 12 Mhz linear transducer and compared to ICP values. In 15 children, a minimum of 2 paired US-ONSD/ICP determinations were performed, and repeated-measures correlation (rmcorr) and intra-individual correlations were analyzed. Results: The cohort correlation between US-ONSD and ICP was moderate (r = 0.504, p < 0.01). Rmcorr (r = 0.91, p < 0.01) and intra-individual correlations (r = 0.956–1) of US-ONSD and ICP were excellent. A mathematical regression equation can be calculated from two paired US-ONSD/ICP values and applied to the individual patient to approximate ICP from US-ONSD. Conclusions: Related to excellent intra-individual correlations between US-ONSD and ICP, an individualized regression formula, created from two pairs of US-ONSD/ICP values, may be used to directly approximate ICP based on US-ONSD values. Hence, US-ONSD may become a non-invasive and reliable measure to control treatment efficacy in pediatric IIH. [ABSTRACT FROM AUTHOR]
Copyright of Brain Sciences (2076-3425) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:20763425
DOI:10.3390/brainsci14010032