دورية أكاديمية

Integrating neuroimaging biomarkers into the multicentre, high-dose erythropoietin for asphyxia and encephalopathy (HEAL) trial: rationale, protocol and harmonisation

التفاصيل البيبلوغرافية
العنوان: Integrating neuroimaging biomarkers into the multicentre, high-dose erythropoietin for asphyxia and encephalopathy (HEAL) trial: rationale, protocol and harmonisation
المؤلفون: Taeun Chang, Brenda Poindexter, Gregory M. Sokol, Patrick J Heagerty, Mark Smith, Jessica L Wisnowski, Amit M Mathur, Jeffrey Berman, Ping-Sun Keven Chen, James Dix, Trevor Flynn, Stanley Fricke, Seth D Friedman, Hayden W Head, Chang Y Ho, Beth Kline-Fath, Michael Oveson, Richard Patterson, Sumit Pruthi, Nancy Rollins, Yanerys M Ramos, John Rampton, Jerome Rusin, Dennis W Shaw, Jean Tkach, Shreyas Vasanawala, Arastoo Vossough, Matthew T Whitehead, Duan Xu, Kristen Yeom, Bryan Comstock, Sandra E Juul, Yvonne W Wu, Robert C McKinstry, Kaashif Ahmed, Mariana Beserga, Ellen Bendel-Stenzel, Lina Chalak, John Flibotte, Fernando Gonzalez, Andrea Lampland, Nathalie Maitre, Amit M. Mathur, Dennis Mayock, Ulrike Mietzsch, Rakesh Rao, David Riley, Krisa Van Meurs, Hendrik Weitkamp, Tai-Wei Wu, Toby Yanowitz
المصدر: BMJ Open, Vol 11, Iss 4 (2021)
بيانات النشر: BMJ Publishing Group, 2021.
سنة النشر: 2021
المجموعة: LCC:Medicine
مصطلحات موضوعية: Medicine
الوصف: Introduction MRI and MR spectroscopy (MRS) provide early biomarkers of brain injury and treatment response in neonates with hypoxic-ischaemic encephalopathy). Still, there are challenges to incorporating neuroimaging biomarkers into multisite randomised controlled trials. In this paper, we provide the rationale for incorporating MRI and MRS biomarkers into the multisite, phase III high-dose erythropoietin for asphyxia and encephalopathy (HEAL) Trial, the MRI/S protocol and describe the strategies used for harmonisation across multiple MRI platforms.Methods and analysis Neonates with moderate or severe encephalopathy enrolled in the multisite HEAL trial undergo MRI and MRS between 96 and 144 hours of age using standardised neuroimaging protocols. MRI and MRS data are processed centrally and used to determine a brain injury score and quantitative measures of lactate and n-acetylaspartate. Harmonisation is achieved through standardisation—thereby reducing intrasite and intersite variance, real-time quality assurance monitoring and phantom scans.Ethics and dissemination IRB approval was obtained at each participating site and written consent obtained from parents prior to participation in HEAL. Additional oversight is provided by an National Institutes of Health-appointed data safety monitoring board and medical monitor.Trial registration number NCT02811263; Pre-result.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2044-6055
العلاقة: https://bmjopen.bmj.com/content/11/4/e043852.fullTest; https://doaj.org/toc/2044-6055Test
DOI: 10.1136/bmjopen-2020-043852
الوصول الحر: https://doaj.org/article/b09a409f0adb4639a6db27d4bf00a9adTest
رقم الانضمام: edsdoj.b09a409f0adb4639a6db27d4bf00a9ad
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20446055
DOI:10.1136/bmjopen-2020-043852