دورية أكاديمية

CFD-Based Numerical Simulation on the Combined Spraying Dust Suppression Device.

التفاصيل البيبلوغرافية
العنوان: CFD-Based Numerical Simulation on the Combined Spraying Dust Suppression Device.
المؤلفون: Mo, Shitu, Wang, Pengfei, Gao, Runze, Chen, Shiqiang, Li, Shilin
المصدر: Atmosphere; Oct2022, Vol. 13 Issue 10, pN.PAG-N.PAG, 21p
مصطلحات موضوعية: COMPUTER simulation, WATER pressure, AIR pressure, WATER consumption, SPRAYING & dusting in agriculture, AIR ducts, DUST, DUST control
مستخلص: Spraying for dust suppression is a conventional technological means for industrial dust control. The traditional spraying technique shows a few shortcomings, including low dust suppression efficiency, great water consumption, and failure in far-distance dust suppression. This study proposed a novel combined spraying dust suppression device and established the related physical model and mathematical model. Using the CFD numerical simulation method, the basic characteristics of the airflow field and spray field around the device and the related influencing factors were investigated in depth. Results showed that the Coanda effect appeared near the wall surface in the air duct when the combined spraying dust suppression device was operated. Under this effect, negative pressure formed at the center of the device. The velocity of the combined device showed a symmetrical distribution and decayed steadily downward from the outlet of the device. An obvious stratification can be observed in the spray field. The mean droplet size first increased and then decreased along the airflow direction. Meanwhile, the effects of the air supply pressure and water supply pressure were examined. On the one hand, the velocity of the combined spraying dust suppression device and the spraying range were in direct proportion with the air supply pressure. As the air supply pressure increased, the droplet size first increased and then decreased. On the other hand, increasing the water supply pressure imposed almost no effect on the airflow field of the combined spraying dust suppression device but can reduce the droplet size and enhance the spraying range. [ABSTRACT FROM AUTHOR]
Copyright of Atmosphere is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:20734433
DOI:10.3390/atmos13101543