Pulsatile Venoarterial Perfusion Using a Novel Synchronized Cardiac Assist Device Augments Coronary Artery Blood Flow During Ventricular Fibrillation.

التفاصيل البيبلوغرافية
العنوان: Pulsatile Venoarterial Perfusion Using a Novel Synchronized Cardiac Assist Device Augments Coronary Artery Blood Flow During Ventricular Fibrillation.
المؤلفون: Cremers, Bodo, Link, Andreas, Werner, Christian, Gorhan, Holger, Simundic, Ivo, Matheis, Georg, Scheller, Bruno, Böhm, Michael, Laufs, Ulrich
المصدر: Artificial Organs; Jan2015, Vol. 39 Issue 1, p77-82, 6p
مصطلحات موضوعية: CARDIOGENIC shock, MYOCARDIAL infarction, SHOCK (Pathology), CARDIAC arrest, ARTIFICIAL organs, VENTRICULAR fibrillation
مستخلص: Patients with cardiogenic shock have a very high mortality. Here we report the first use of a percutaneous pulsatile cardiac assist device, based on a diagonal pump synchronized with the heart cycle by means of an electrocardiographic signal in adult pigs. Eight domestic pigs underwent mandatory ventilation. During sinus rhythm, there were no differences between pulsatile and nonpulsatile perfusion with regard to pulmonary artery pressure, pulmonary wedge pressure, central venous pressure, mean arterial pressure ( MAP), mean pulse pressure, and mean coronary artery flow ( CAF). After 2 min of complete cardiac arrest (ventricular fibrillation), circulatory support with the i-cor in venoarterial nonpulsatile extracorporeal membrane oxygenation ( ECMO) mode (3 L/min) restored systemic circulation, with an increase of MAP to 78.3 mm Hg and CAF to 5.27 mL/min. After changing from ECMO settings to pulsatile mode (3 L/min, 75 bpm, pulse amplitude range 3500 rpm), MAP did not change significantly (75.6 mm Hg); however, CAF increased to 8.45 mL/min. After changing back to nonpulsatile mode, MAP remained stable (83.6 mm Hg), but CAF decreased to 4.85 mL/min. Thereafter, pulsatile cardiac assist was established with a reduced blood flow of 2.5 L/min, and the pulse amplitude range was extended to 4500 rpm. Under these conditions, MAP remained stable (71.0 mm Hg), but CAF significantly increased to 15.2 mL/min ( P < 0.05). Percutaneous cardiac support using a venoarterial cardiac assist device equipped with a novel diagonal pump is able to restore and increase systemic and coronary circulation during ventricular fibrillation. Electrocardiographically triggered synchronized cardiac assist provides an additional increase of coronary artery flow. These promising results are to be confirmed in humans. [ABSTRACT FROM AUTHOR]
Copyright of Artificial Organs is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:0160564X
DOI:10.1111/aor.12413