New fontanometer for continuous estimation of intracranial pressure in the newborn

التفاصيل البيبلوغرافية
العنوان: New fontanometer for continuous estimation of intracranial pressure in the newborn
المؤلفون: Andrew R. Wilkinson, P Rolfe, M J Rochefort
المصدر: Archives of Disease in Childhood. 62:152-155
بيانات النشر: BMJ, 1987.
سنة النشر: 1987
مصطلحات موضوعية: Brain Diseases, medicine.medical_specialty, Intracranial Pressure, business.industry, Fontanelle, Encephalopathy, Infant, Newborn, medicine.disease, Infant newborn, Infant, Newborn, Diseases, Surgery, Raised intracranial pressure, Hydrocephalus, medicine.anatomical_structure, Anesthesia, Intensive care, Pediatrics, Perinatology and Child Health, medicine, Humans, Cerebrospinal fluid pressure, business, Monitoring, Physiologic, Research Article, Intracranial pressure
الوصف: Intracranial pressure was estimated by a new pneumatic applanation fontanometer in babies in intensive care. A close correlation with cerebrospinal fluid pressure was found on 35 separate occasions. In 12 control babies the mean (SD) fontanelle pressure was 5.2 (2.2) cm H2O, in eight with a hypoxic-ischaemic encephalopathy it was 12.6 (4.3) cm H2O, and in nine with post-haemorrhagic hydrocephalus it was 10.8 (4.3) cm H2O. In four babies monitored continuously over seven days the correlation remained good. The fontanometer enables pressure to be monitored accurately, continuously, and non-invasively in neonates at risk of raised intracranial pressure.
تدمد: 1468-2044
0003-9888
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4103c4962a8e1599880e25bfc287edf5Test
https://doi.org/10.1136/adc.62.2.152Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....4103c4962a8e1599880e25bfc287edf5
قاعدة البيانات: OpenAIRE