دورية أكاديمية

Revising Expectations from Rapid HIV Tests in the Emergency Department.

التفاصيل البيبلوغرافية
العنوان: Revising Expectations from Rapid HIV Tests in the Emergency Department.
المؤلفون: Walensky, Rochelle P., Arbelaez, Christian, Reichmann, William M., Walls, Ron M., Katz, Jeffrey N., Block, Brian L., Dooley, Matthew, Hetland, Adam, Kimmel, Simeon, Solomon, Jessica D., Losina, Elena
المصدر: Annals of Internal Medicine; 8/5/2008, Vol. 149 Issue 3, p153-160, 9p, 2 Charts
مصطلحات موضوعية: HIV infections, HIV-positive persons, ENZYME-linked immunosorbent assay, HIV, PATIENTS
مصطلحات جغرافية: UNITED States
مستخلص: Background: Expanded HIV screening efforts in the United States have increased the use of rapid HIV tests in emergency departments. The reported sensitivity and specificity of rapid HIV tests exceed 99%. Objective: To assess whether a reactive rapid oral HIV test result correctly identifies adults with HIV infection in the emergency department. Design: Diagnostic test performance assessment within the framework of a randomized, clinical trial. Setting: Brigham and Women's Hospital emergency department (Boston, Massachusetts) from 7 February to 1 October 2007. Patients: 849 adults with valid rapid oral HIV test results. Intervention: Rapid HIV testing with the OraQuick ADVANCE Rapid HIV-1/2 Antibody Test (OraSure Technologies, Bethlehem, Pennsylvania). Patients with reactive rapid test results were offered enzyme-linked immunoassay, Western blot, and plasma HIV-1 RNA testing for confirmation. Measurements: Specificity and positive likelihood ratio. Results: 39 patients had reactive results (4.6% [95% CI, 3.2% to 6.0%]). On confirmation, 5 patients were HIV-infected (prevalence, 0.6% [CI, 0.1% to 1.1%]) and 26 were non-HIV-infected (8 patients declined confirmation). The estimated rapid test specificity was 96.9% (CI, 95.7% to 98.1%). Sensitivity analyses of the true HIV status of unconfirmed cases and test sensitivity resulted in a positive likelihood ratio of 8 to 32. Western blot alone as a confirmation test provided conclusive HIV status in only 50.0% (CI, 30.8% to 69.2%) of patients at first follow-up. The addition of HIV-1 RNA testing to the confirmation protocol improved this rate to 96.2% (CI, 88.8% to 100.0%). Limitation: Test sensitivity cannot be assessed because nonreactive OraQuick test results were not confirmed. Conclusion: Although patients with a reactive oral OraQuick HIV screening test in the emergency department had an 8- to 32-fold increased odds of HIV infection compared with the pretest odds, the specificity of the test was lower than anticipated. [ABSTRACT FROM AUTHOR]
Copyright of Annals of Internal Medicine is the property of American College of Physicians and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00034819
DOI:10.7326/0003-4819-149-3-200808050-00003